10 Channel Data Logger
10 Channel Data Logger

10 Channel Data Logger

10 Channel Data Logger Specification

  • Accuracy
  • ±0.1% FS
  • Test Range
  • ---
  • Equipment Type
  • 10 Channel Data Logger
  • Power Supply
  • 230V AC, 50Hz
  • Display Type
  • Digital LCD Display
  • Gas Pressure
  • ---
  • Humidity
  • ---
  • Resolution
  • 16 Bit
  • Port Size
  • ---
  • Hardness
  • ---
  • Frequency
  • 50Hz
  • Features
  • Data Storage, Multi-channel monitoring, Alarm Output, Portable
  • Number of Specimens
  • ---
  • Specimen Size
  • ---
  • Temperature
  • 0°C to 50°C
  • Measuring Range
  • ---
  • Interface Type
  • USB / RS232
  • Response Time
  • 1 Second
  • Mounting Type
  • Table Top
  • Max Height
  • ---
  • Operating Voltage
  • 230V AC
  • Automation Grade
  • Semi-Automatic
  • Application
  • Industrial Data Logging
  • Usage
  • Industrial, Laboratory
  • Capacity
  • ---
  • Machine Weight
  • 4.8 Kg
  • Test Speed
  • ---
  • Test Width
  • ---
  • Test Stroke
  • ---
  • Control Mode
  • Manual / PC Software
  • Alarm Output
  • Buzzer / Relay
  • Data Storage Capacity
  • 50,000 Readings
  • Clock
  • Inbuilt Real Time Clock
  • Sensor Input Type
  • Universal (Thermocouple, RTD, Voltage, Current)
  • Equipment Type
  • 10 Channel Data Logger
  • Software Compatibility
  • Windows compatible
  • Number of Channels
  • 10
  • Dimensions
  • 250 x 165 x 120 mm
  • Ingress Protection
  • IP20
  • Data Output Format
  • CSV
  • Sampling Rate
  • Programmable
  • Enclosure Material
  • ABS Plastic
  • Battery Backup
  • Inbuilt Rechargeable Battery (2 Hrs)
 
 

About 10 Channel Data Logger

10 Channel Data Logger

Display 16 x 2 Line LCD Display with back light
No. Of Channels 10 Channel
Power Supply 230V +/-10% @ 50Hz.
Temperature Range K-type Thermocouple ( 0 -700 Deg C)
ADC Resolution 16 Bit
Scan Range 1 to 100 samples/sec Menu settable 1 to 9
Auto / Manual Settable through Menu.
Signal Conditioning Signal Conditioning for Pressure and K-type Thermocouple inbuilt.
Pressure Sensor Piezo-resistive type Capacity 5PSI 0 to 200 mmWc. (Vacuum)
Load Cell Strain guage based Capacity 3.000kgms 0 to 3.000kgms
Speed Proximity sensor (PNP-Type) (0 -3000 RPM)
Date & Time RTC is provided with Battery backup.



Multi-Channel Versatility

With 10 universal input channels, this data logger supports a wide range of sensors including thermocouples, RTDs, voltage, and current, allowing simultaneous monitoring of multiple parameters. This makes it ideal for complex industrial and laboratory applications where capturing varied data points is critical for analysis.


Reliable Data Storage & Export

The logger accommodates up to 50,000 data points, ensuring extended recording without data loss. Exporting data is seamless through USB or RS232 interfaces, and the readings are saved in a user-friendly CSV format compatible with Windows software, simplifying subsequent analysis and documentation tasks.


Efficient Alarm & Backup Features

Equipped with both buzzer and relay alarm outputs, the device promptly alerts users to out-of-range values. Its inbuilt rechargeable battery provides up to 2 hours of backup operation, ensuring data integrity during power interruptions. The durable ABS enclosure and IP20 ingress protection support longevity in diverse industrial settings.

FAQ's of 10 Channel Data Logger:


Q: How do I connect sensors to the 10 Channel Data Logger?

A: You can connect a variety of sensors-including thermocouples, RTDs, voltage, and current sources-using each of the 10 universal input channels. Simply follow the corresponding input wiring instructions provided in the user manual to ensure accurate measurements.

Q: What is the process for retrieving stored data from the logger?

A: Stored data can be exported via the USB or RS232 interface in CSV format. Once connected to a Windows-compatible computer, use the supplied software to transfer, view, and analyze your recorded readings quickly and efficiently.

Q: When should I use the alarm output feature?

A: The alarm output feature, including buzzer and relay, is ideal for situations requiring immediate attention to out-of-range or abnormal values. You can program the logger to activate alarms based on defined measurement thresholds for swift responses during critical processes.

Q: Where can this data logger be installed?

A: This data logger is suitable for tabletop installation in controlled environments such as industrial facilities, laboratories, and automation systems. Its IP20 ABS plastic enclosure provides basic protection against dust and accidental contact.

Q: What benefits does the built-in battery backup provide?

A: The integrated rechargeable battery offers up to 2 hours of operation during power outages, ensuring uninterrupted data logging and protection against data loss. This is particularly useful in industrial environments where power reliability may be a concern.

Q: How can the sampling rate be adjusted on the device?

A: The sampling rate is programmable, allowing users to set the frequency of data collection according to specific application requirements. Adjustments can be made directly from the device interface or through the compatible Windows software.

Q: What advantages does the digital LCD display offer during usage?

A: The digital LCD display provides clear, real-time visualization of all monitored channels and system settings, making it easy to track sensor data, status notifications, and clock readings without requiring a computer connection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing And Measuring Equipments Category

L.D.R Trainer

L.D.R Trainer

Humidity : 40% 80% RH

Resolution : 0.01 mm

Control Mode : Manual

Display Type : Digital

Equipment Type : L.D.R Trainer

Test Range : 0 99 (Relative Value)

Analgesiometer With Pid Controller

Analgesiometer With Pid Controller

Humidity : 10% to 90% RH (Noncondensing)

Resolution : 1 g

Control Mode : Microprocessorbased PID Controller

Display Type : Digital LED Display

Equipment Type : Digital Analgesiometer with PID Controller

Test Range : Up to 500 g

Displacement Measurement Trainer

Displacement Measurement Trainer

Humidity : 20% to 80% RH

Resolution : 0.01 mm

Control Mode : Manual and Automatic

Display Type : Digital LCD

Equipment Type : Displacement Measurement Trainer

Test Range : 0100 mm

Basic Pneumatic Trainer

Basic Pneumatic Trainer

Humidity : 20% 80% RH (noncondensing)

Resolution : Depends on instrument module

Control Mode : Manual

Display Type : Analog/gaugebased

Equipment Type : Pneumatic Trainer

Test Range : Basic pneumatic applications



Back to top