  • Type
  • Susceptibility Measurement Apparatus
  • Material
  • Non-magnetic metal body with glass fittings
  • Size
  • Standard laboratory
  • Input Voltage
  • 230V AC
  • Color
  • Stainless steel and transparent glass
  • Dimension (L*W*H)
  • Meter tube: 30 cm length, overall frame: 50 x 15 x 20 cm
  • Capacity
  • Supports samples up to 10 grams
  • Noise Level
  • Silent operation
  • Calibration
  • Factory calibrated, user adjustable
  • Application
  • Measurement of paramagnetic and diamagnetic properties
  • Mounting
  • Table-top with anti-vibration feet
  • Accessories Included
  • Sample holders, calibration weights, operational guide
  • Meter Tube Material
  • Precision borosilicate glass
  • Power Consumption
  • Low (<10W)
  • Temperature Range
  • Ambient laboratory temperatures (15°C to 35°C)
  • Safety Features
  • Protective glass casing, overload protection
  • Scale Resolution
  • 0.001 g
  • Display Type
  • Analog scale with fine indicator
  • Working Principle
  • Determines magnetic susceptibility by differential weighing
  • Measurement Method
  • Gouy balance principle
  • Sample Chamber Diameter
  • 14 mm
 
 

About APPARATUS FOR THE MEASUREMENT OF SUSCEPTIBLITY



Discover the rare and matchless APPARATUS FOR THE MEASUREMENT OF SUSCEPTIBILITY-a must-have for laboratories aiming for precision and efficiency. This virtuoso device utilizes the Gouy balance principle, providing an uncommon scale resolution of 0.001 g and an analog display with a fine indicator. The apparatus features a precision borosilicate glass meter tube, robust non-magnetic metal body, and supports samples up to 10 grams. Enjoy a substantial discount from industry-leading distributor, exporter, and manufacturer in India. Comes factory-calibrated with sample holders, calibration weights, and protective glass casing for safe, silent operation. Unrivaled in quality and reliability.

Versatile Laboratory Applications

The APPARATUS FOR THE MEASUREMENT OF SUSCEPTIBILTY is primarily used for accurate determination of magnetic susceptibility in both paramagnetic and diamagnetic materials. It finds broad application in research laboratories, educational institutes, and quality control settings. Designed for straightforward usage, it allows precise sample analysis with included calibration accessories, making it ideal for scientific studies, chemical analysis, and material testing.


Certifications and Reliable Dispatch

Our apparatus is certified for quality and safety, ensuring compliance with international standards. Served throughout India, it is dispatched efficiently via trusted goods transport partners and is safely packed and dispatched from recognized FOB ports. Each unit undergoes meticulous packing to ensure it reaches you in optimal condition, providing peace of mind and reliability for domestic and export requirements.


FAQ's of APPARATUS FOR THE MEASUREMENT OF SUSCEPTIBLITY:


Q: How does the apparatus measure magnetic susceptibility?

A: The apparatus employs the Gouy balance principle, determining magnetic susceptibility by measuring the differential weight of a sample in a magnetic field using precision analog scales.

Q: What types of materials can be tested using this apparatus?

A: It is designed to measure both paramagnetic and diamagnetic materials, making it suitable for a wide variety of chemical and material science applications.

Q: When should calibration be performed on the apparatus?

A: The apparatus comes factory-calibrated, but users can perform additional calibration before critical measurements or periodically to ensure ongoing accuracy.

Q: Where can this apparatus be used?

A: This instrument is ideal for laboratory environments, including research institutes, academic labs, and industrial testing facilities requiring accurate susceptibility measurements.

Q: What safety features are included with the apparatus?

A: It features a protective borosilicate glass casing and overload protection to ensure operator safety and maintain sample integrity during measurement.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

DSPIC30F4011 BASED SPEED CONTROL (V/F) OF 3PH AC INDUCTION MOTOR

DSPIC30F4011 BASED SPEED CONTROL (V/F) OF 3PH AC INDUCTION MOTOR

Capacity : Up to 3HP (depending on connected induction motor)

Size : Standard module size

Dimension (L*W*H) : Approx. 180mm x 130mm x 35mm

Color : Multicolor PCB with graphical printed overlay

Material : PCB, Electronic Components, Enclosure

Noise Level : Low

STAND FOR MERCURY LAMP

STAND FOR MERCURY LAMP

Capacity : Supports up to 400W Lamp

Size : Standard

Dimension (L*W*H) : Approx. 18 inch x 14 inch x 36 inch

Color : White

Material : Mild Steel

Noise Level : Silent Operation

AUDIO FREQUENCY FUNCTION GENERATOR 0-200KHz

AUDIO FREQUENCY FUNCTION GENERATOR 0-200KHz

Capacity : Output Frequency Range: 0200 KHz

Size : Standard benchtop instrument

Dimension (L*W*H) : 230 x 210 x 90 mm

Color : Grey

Material : Highquality electronic components and metal casing

Noise Level : Low

UNIVERSAL MOTOR CONTROL USING AC-DC CONTROLLER (SCR, TRIAC BASED)

UNIVERSAL MOTOR CONTROL USING AC-DC CONTROLLER (SCR, TRIAC BASED)

Capacity : Up to 1 HP Motor Load

Size : Standard Module

Dimension (L*W*H) : 185 mm x 120 mm x 65 mm

Color : Green (PCB), Multicolor Components

Material : Industrial Grade PCB, Electronic Components

Noise Level : Low



Back to top