Current To Pressure Measurement Trainer
Current To Pressure Measurement Trainer

Current To Pressure Measurement Trainer

Current To Pressure Measurement Trainer Specification

  • Features
  • Safe operation with built-in over-voltage protection, easy troubleshooting, schematic front panel
  • Display Type
  • Digital LCD
  • Shape
  • Rectangular
  • Power Supply
  • 230 V AC Mains
  • Temperature Resistance
  • Up to 80C
  • Control Type
  • Manual and Auto
  • Glass Type
  • Acrylic Panel
  • Accuracy
  • 1% of Full Scale
  • Type
  • Bench Top Trainer
  • Dimension (L*W*H)
  • 45 cm x 30 cm x 20 cm
  • Equipment Type
  • Measurement Trainer
  • Equipment Materials
  • Powder Coated MS Sheet, SS Fittings
  • Power
  • 230 V AC, 50 Hz
  • Voltage
  • 230 V
  • Material
  • Mild Steel Body
  • Application
  • Instrumentation Lab, Current to Pressure Calibration
  • Operating Environment
  • Indoor, lab environment
  • Compliance
  • Meets standard laboratory safety guidelines
  • Construction
  • Portable modular design with robust mounting
  • Panel Type
  • Laminated schematic panel
  • Accessories Supplied
  • Test leads, connection pipes, instruction manual
  • Input Signal Range
  • 4-20 mA
  • Valve Type
  • I/P Converter valve
  • Protection
  • Short-circuit and overload protection
  • Interface
  • Banana sockets and pneumatic ports
  • Output Pressure Range
  • 3-15 PSI
  • Pressure Sensor
  • Integrated, electronic type
  • Calibration Facility
  • Inbuilt with multi-point test selector
  • Mounting
  • Table Top
  • Weight
  • Approx. 9 kg
  • Test Points
  • Multiple test points for performance verification
  • Training Suitability
  • Ideal for academic and industrial training
 
 

About Current To Pressure Measurement Trainer

Current To Pressure Measurement Trainer

Brand Micro Technologies
Display Type 31/2 digit LED display
Resolution 0-1mA
I to P Input 4 to 20mA. Output 3 to 15 PSI
Air Pressure Required 30 to 80 PSI continues.
Pressure Gauge Bourdon pressure gauge 30 PSI 4"-2 No's
Current o/p 4 to 20mV Variable by a potentiometer.
Power Supply 230V 50 Hz
Accessories Supplied Air Regulator with fitter. Necessary tubings and cable.
Optional Air compressor at extra cost.



Comprehensive Training Solution for Instrumentation

The Current To Pressure Measurement Trainer is specifically tailored for academic and industrial environments, offering hands-on experience with state-of-the-art measurement and calibration techniques. Its user-friendly design and detailed schematic panel empower both students and professionals to understand I/P conversion principles and system troubleshooting effectively.


Reliable Performance and Safety Features

Constructed with high-quality materials such as powder-coated mild steel and stainless steel fittings, the trainer boasts durable performance and excellent safety. Integrated protection against short-circuit and overload, along with voltage surge protection, ensures safe operation even in rigorous lab settings.


Flexible Usage and Easy Maintenance

The trainer includes all necessary accessories like test leads, connection pipes, and an instruction manual for immediate use. Its portable, table top build and multiple mounting options make it suitable for diverse setups, while the digital LCD display simplifies real-time data monitoring and system checks.

FAQ's of Current To Pressure Measurement Trainer:


Q: How does the Current To Pressure Measurement Trainer function?

A: The trainer converts a 4-20 mA input electrical signal into a proportional pneumatic output pressure ranging from 3-15 PSI using an I/P converter valve and integrated electronic sensor, enabling precise current-to-pressure calibration and measurement.

Q: What makes this trainer suitable for both academic and industrial training?

A: Its modular, portable construction, inbuilt multipoint calibration, and safety-compliant design with clear schematic front panel provide a practical learning experience for students as well as skill enhancement for professionals in industrial settings.

Q: When should I use the calibration facility?

A: Calibration should be performed before initial use, after maintenance, or whenever measurement accuracy is in question, utilizing the inbuilt multi-point test selector for reliable performance verification.

Q: Where can this trainer be operated?

A: This equipment is intended for indoor laboratory environments, particularly on table tops in instrumentation labs or training rooms, ensuring a controlled and safe working space.

Q: What are the steps for operating the trainer safely?

A: Begin by connecting the supplied test leads and pipes, power on the unit (230V AC), then follow the instruction manual to set input signals and observe output pressures. Always use the trainer within designated temperature and voltage limits, and refer to test points for performance checks.

Q: What are the main benefits of using this trainer?

A: Users gain practical experience in current-to-pressure conversion, calibration, and system troubleshooting with high accuracy (1% full scale), benefiting from easy maintenance, safe operation, and a comprehensive training platform backed by robust construction.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware And Equipments Category

Bottle Washing Machine

Bottle Washing Machine

Material : Stainless Steel

Application : Washing bottles in pharmaceutical, food & beverage, chemical industries

Type : Other, Automatic Rotary Bottle Washing Machine

Control Type : PLC based control

Dimension (L*W*H) : 1200 mm x 900 mm x 1500 mm

Features : Compact design, hygienic operation, low maintenance, adjustable bottle holders

Melting Point Apparatus : Digital (Economical)

Melting Point Apparatus : Digital (Economical)

Material : Metal and glass

Application : Determination of melting point of substances

Type : Other, Digital (Economical)

Control Type : Digital control with adjustment knob

Dimension (L*W*H) : Approx. 250 mm x 175 mm x 150 mm

Features : Quick heating, easy operation, clear display

Stainless Steel Stainless Steel Slide Warming Table

Stainless Steel Stainless Steel Slide Warming Table

Material : Stainless Steel

Application : Slide warming, Histopathology laboratory use

Type : Other, Stainless Steel Slide Warming Table

Control Type : Digital Temperature Controller

Dimension (L*W*H) : 1200 x 600 x 850 mm

Features : Uniform heating, Corrosion resistance, Easy to clean surface

Lab Willey Grinder

Lab Willey Grinder

Material : Mild Steel and Stainless Steel Contact Parts

Application : Grinding of dry laboratory samples, plant material, and pharmaceuticals

Type : Other, Willey Grinder

Control Type : Manual On/Off Switch

Dimension (L*W*H) : 40 x 25 x 45 cm (approx.)

Features : Easy to operate, robust construction, low maintenance, fitted with hopper and sieve, stainless steel blades



Back to top