FABRY-PEROT ETALON
FABRY-PEROT ETALON

FABRY-PEROT ETALON

FABRY-PEROT ETALON Specification

  • Type
  • Fabry-Perot Etalon
  • Material
  • Optical Glass
  • Size
  • Customizable
  • Color
  • Transparent/Coated
  • Dimension (L*W*H)
  • As per requirement
  • Clear Aperture
  • 10 mm (standard); custom on request
  • Optical Flatness
  • /10 @ 632.8 nm
  • Reflectivity
  • Up to 97% as specified
  • Finesse
  • 30 (typically higher on request)
  • Parallelism
  • < 1 arc second
  • Surface Quality
  • 10-5 scratch dig
  • Wavelength Range
  • 400 nm 2000 nm
  • Operating Temperature
  • -20C to 70C
  • Free Spectral Range (FSR)
  • 10 GHz 1000 GHz (custom options available)
  • Coating Options
  • Dielectric, metallic, or custom as needed
  • Applications
  • Spectroscopy, laser tuning, wavelength filtering, telecommunications
 
 

About FABRY-PEROT ETALON



Discover the virtuoso in optical performance with the FABRY-PEROT ETALON, engineered for instant savings and cost-effective procurement. Boasting a wavelength range from 400 nm to 2000 nm, finest surface quality of 10-5 scratch dig, and finesse 30 (higher available on request), it's perfect for applications needing unmatched precision and reliability. Reflectivity reaches up to 97%, with customizable FSR, aperture, and coatings. Procure as distributor, exporter, manufacturer, supplier, or trader from India for tailoring to your specifications. Achieve excellence in spectroscopy, laser tuning, and more, with industry-leading quality.

Features, Applications & Specific Usage

The FABRY-PEROT ETALON stands out with its customizable clear aperture (standard 10 mm), optical flatness of /10 @ 632.8 nm, and parallelism under 1 arc second. Perfect for spectroscopy, wavelength filtering, laser tuning, and telecommunications, this precision instrument delivers reliable results in laboratory, industrial, and research environments. Its versatile coatings and robust operating temperature range make it ideal for both routine and advanced scientific applications, providing users with the finest control over spectral analysis.


Export Markets, Sample Policy & Payment Terms

FABRY-PEROT ETALON enjoys strong arrival in global and domestic markets, notably Asia, Europe, and North America, with the lowest price assurance and flexible trading conditions. Sample policy is designed for easy evaluation, enabling prospective clients to test product virtues before marking a full-scale purchase. Payment terms offer convenience and security, supporting transactions via trusted channels. Its timely delivery, tailored customization, and cost-efficiency uphold international standards and foster long-term business relationships.


FAQ's of FABRY-PEROT ETALON:


Q: How can I procure the FABRY-PEROT ETALON for my laboratory or industrial use?

A: You can procure the FABRY-PEROT ETALON directly from us as a distributor, exporter, manufacturer, supplier, or trader in India. Custom options are available to match your specific requirements-simply contact our sales team for guidance and quotations.

Q: What benefits does the high finesse and reflectivity of this etalon provide?

A: High finesse and reflectivity enable superior spectral resolution and precise wavelength selection, which are essential for advanced spectroscopy, laser tuning, and optimal filtering performance in demanding research and industrial applications.

Q: When should I consider using a custom FSR or specialized coating?

A: Custom Free Spectral Range or bespoke coatings should be considered when applications demand tailored wavelength selectivity or unique environmental resistance. Our team can advise on the most suitable options based on your operational needs.

Q: Where is the FABRY-PEROT ETALON most commonly used?

A: The etalon is commonly used in scientific laboratories, telecommunications setups, and industrial process environments where precise spectral analysis, filtering, or laser tuning is required for top-tier results.

Q: What is the process for requesting a sample before placing a bulk order?

A: To request a sample, simply reach out through our sample policy channels. We will assist with sample selection, customization if needed, and provide clear instructions to ensure you receive an etalon meeting your evaluation needs before confirming a larger purchase.

Q: How does optical flatness and surface quality impact the etalon's performance?

A: Superior optical flatness and pristine surface quality (10-5 scratch dig) minimize scattering and aberrations, ensuring the finest transmission and reflection characteristics vital for high-precision optical measurement and analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

MONOSTABLE MULTIVIBRATOR TRAINER (USING TRANSISTOR)

MONOSTABLE MULTIVIBRATOR TRAINER (USING TRANSISTOR)

Type : Other, Monostable Multivibrator Trainer (Using Transistor)

Material : Highquality PCB with mounted discrete components

Size : Standard laboratory trainer size

Dimension (L*W*H) : Approx. 260 x 170 x 80 mm

Color : Multicolor (typically green PCB with labeling and colored components)

Capacity : Single circuit demonstration

FULL WAVE RECTIFIER

FULL WAVE RECTIFIER

Type : Other, FULL WAVE RECTIFIER

Material : Highgrade semiconductor materials

Size : Standard module size

Dimension (L*W*H) : 90mm x 60mm x 20mm

Color : Black

Capacity : 5A max output current

METER RULE

METER RULE

Type : Other, Meter Rule

Material : Stainless Steel

Size : 1 Meter

Dimension (L*W*H) : 1000 mm x 25 mm x 1 mm

Color : Silver



Back to top