Hot Plate Type Soxhlet Extraction Unit Specification

  • Display Type
  • Analog / Indicator Lamp
  • Control Type
  • Individual energy regulators
  • Heating Capacity
  • Adjustable, up to 350°C
  • Shape
  • Rectangular
  • Temperature Resistance
  • Up to 350°C
  • Features
  • Detachable individual heaters, Powder coated body, Corrosion resistance
  • Glass Type
  • Borosilicate Glassware
  • Power Supply
  • Electric, 220-240V
  • Accuracy
  • ±2°C (Temperature Control)
  • Type
  • Hot Plate Type Soxhlet Extraction Unit
  • Dimension (L*W*H)
  • 450 x 270 x 360 mm
  • Equipment Type
  • Laboratory Extraction Unit
  • Equipment Materials
  • Mild Steel, Borosilicate Glass
  • Power
  • 800 W per hot plate
  • Voltage
  • 220-240V AC, 50 Hz
  • Material
  • Mild Steel Body with Epoxy Powder Coating
  • Application
  • Fat Extraction, Solvent Extraction in Laboratory
  • Capacity (Ltr)
  • 500 ml per extraction flask
  • Finish
  • Epoxy powder-coated for chemical resistance
  • Glassware Included
  • Flasks, condensers, siphon tubes, and extraction chambers
  • Extraction Time
  • Typically 2-6 hours (depending on sample)
  • Cooling Method
  • Water-cooled condenser
  • No. of Units
  • Available in 3, 6, or 12 place configurations
  • Extractor Type
  • Multiple/Individual heating mantle with flask arrangement
  • Protection
  • Fused protection for each heating element
  • Operation Mode
  • Manual
  • Safety
  • Overheat protection
  • Heater Type
  • Hot plate heater with individual controls
  • Mounting
  • Bench-top model
  • Net Weight
  • Approx. 18-22 kg (depending on configuration)
 
 

About Hot Plate Type Soxhlet Extraction Unit

Hot Plate Type Soxhlet Extraction Unit

Brand Micro Technologies
Color White
Voltage 230 V
Frequency 50 Hz
Heating Temperature Up to 300 Deg C
Usage/Application Laboratory
Finish Powder Coated



Flexible Multi-Sample Extraction Capability

Accommodating 3, 6, or 12 extraction flasks, this unit is designed for laboratories with varying throughput needs. Each station is independently heated with detachable hot plates, allowing simultaneous or staggered extraction processes. The system is manual, giving users full operational control and making it suitable for both routine and specialized applications such as fat and solvent content estimation.


Precision and Safety Focused

Every extraction station features an individual energy regulator and analog display or indicator lamp, ensuring precise control of temperature (up to 350C) for consistent results. Fused protection for each heater, alongside integrated overheat protection, safeguards both users and samples. The powder-coated exterior offers durability and excellent resistance against harsh chemicals.


Robust Laboratory Construction and Glassware

Manufactured with a mild steel body and borosilicate glass components, the unit withstands demanding laboratory environments. The epoxy powder-coated finish protects against corrosion, while the water-cooled condenser assures effective sample cooling and solvent recovery. Its compact, rectangular bench-top structure fits neatly in most lab spaces, supporting efficient workflow.

FAQs of Hot Plate Type Soxhlet Extraction Unit:


Q: How does the Hot Plate Type Soxhlet Extraction Unit operate in a laboratory setting?

A: This Soxhlet extraction unit uses individual hot plate heaters, each regulated separately, to heat the extraction flasks. The system operates manually, allowing precise control over process timing and temperature. Glassware assemblies include flasks, condensers, siphon tubes, and extraction chambers, enabling efficient solvent extraction for applications like fat analysis.

Q: What are the benefits of having individually controlled hot plates in this extraction unit?

A: Individually controlled hot plates ensure that each position can be set to a specific temperature, providing optimal conditions for simultaneous or different extractions. This enhances productivity and allows researchers to tailor extraction protocols for various sample requirements.

Q: When should I use a multiple-position extraction unit instead of a single-place model?

A: A multi-position unit is recommended when higher sample throughput is required or when multiple samples need to be processed under similar or varying conditions. Laboratories conducting routine quality control or research testing often prefer these configurations to save time and improve workflow.

Q: Where is this Soxhlet extraction unit typically installed?

A: This model is a bench-top unit, suitable for placement on standard laboratory benches. Its compact dimensions (450 x 270 x 360 mm) make it ideal for most laboratory environments, including research facilities, quality control labs, and academic settings.

Q: What safety features are integrated into the Soxhlet extraction unit?

A: The unit incorporates fused protection for each heating element and overheat protection to prevent damage and ensure user safety. The epoxy powder-coated finish also adds chemical and corrosion resistance, enhancing durability.

Q: How long does the extraction process typically take with this unit?

A: Extraction time generally ranges between 2 to 6 hours, depending on the sample type, solvent used, and extraction parameters set by the operator. The units adjustable heating enables fine-tuning for optimal extraction efficiency.

Q: What is included with the Hot Plate Type Soxhlet Extraction Unit package?

A: Each unit comes equipped with borosilicate glassware: extraction flasks (500 ml capacity), condensers, siphon tubes, and extraction chambers. All necessary components for immediate setup and extraction are provided.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware And Equipments Category

Water Bath Rectangular (Single Wall)

Water Bath Rectangular (Single Wall)

Dimension (L*W*H) : 300 x 250 x 150 mm, 400 x 300 x 150 mm, and other sizes available

Features : Rust proof interior, uniform temperature distribution, easy to clean, overheat protection

Equipment Materials : Stainless Steel inner, Mild Steel outer with epoxy powder coating

Type : Other, Rectangular Single Wall Water Bath

Shape : Rectangular

Equipment Type : Laboratory Water Bath

Water Still Manasty Type

Water Still Manasty Type

Dimension (L*W*H) : Approx. 110 mm x 380 mm x 650 mm

Features : Automatic safety cutoff, easy to clean, energy efficient, wallmountable

Equipment Materials : Borosilicate glass condenser and heater housing, Stainless steel stand

Type : Other, Manasty Type

Shape : Vertical cylindrical

Equipment Type : Distillation Unit

Projection Screen (Map Type)

Projection Screen (Map Type)

Dimension (L*W*H) : Available in multiple sizes (common: 6 x 4 feet, 8 x 6 feet, customized sizes possible)

Features : Easy to mount, smooth rolling mechanism, high brightness, washable, mildew resistant, flame retardant

Equipment Materials : Heavyduty spring roller and mounting brackets

Type : Other, Map Type Projection Screen

Shape : Rectangular

Equipment Type : Projection Screen Wall Map Type

Wall Hanging Projection Screen

Wall Hanging Projection Screen

Dimension (L*W*H) : Customized / As per requirement

Features : Wrinkleresistant surface, Easy installation, Smooth rolling mechanism, Lightweight

Equipment Materials : Steel Casing, High Quality PVC Screen Material

Type : Other, Wall Hanging Projection Screen

Shape : Rectangular

Equipment Type : Projection Screen



Back to top