Kjeldahl Distillation
Kjeldahl Distillation

Kjeldahl Distillation

Kjeldahl Distillation Specification

  • Display Type
  • Analog
  • Power Supply
  • Electric
  • Features
  • Corrosion resistant, easy to clean, efficient distillation, safety features included
  • Speed Range
  • N/A (Not applicable for distillation unit)
  • Heating Capacity
  • Adjustable
  • Temperature Resistance
  • Up to 300°C
  • Shape
  • Rectangular cabinet
  • Glass Type
  • Borosilicate Glass
  • Accuracy
  • High precision, suitable for laboratory analysis
  • Control Type
  • Manual
  • Type
  • Manual, Lab-Scale
  • Dimension (L*W*H)
  • 500 x 400 x 600 mm (Approx.)
  • Equipment Type
  • Laboratory Distillation Unit
  • Equipment Materials
  • Mild steel cabinet with powder coating and borosilicate glass parts
  • Power
  • 500 W to 1500 W (depending on model)
  • Voltage
  • 220 V AC, 50 Hz
  • Material
  • Borosilicate glass, Mild steel
  • Application
  • Determination of nitrogen content by Kjeldahl method
  • Capacity (Ltr)
  • 500 ml to 1000 ml (distillation flask)
  • Safety
  • Over-heating protection and insulated cabinet
  • Burette Volume
  • 50 ml or as required
  • Distillation Flask Support
  • Spring or clamp support system
  • Drip Tip Material
  • PTFE
  • Heating Mantle Type
  • Fixed or replaceable heating mantle
  • Suitable For
  • Educational, analytical, research labs
  • Fume Removal
  • With or without suction/fume evacuation system
  • No. of Distillation Units
  • 1 to 6 units (as per configuration)
  • Condensers
  • High-efficiency glass condenser
 
 

About Kjeldahl Distillation

Kjeldahl Distillation

Usage/Application Distillation unit
Material Mild Steel
Brand Micro Technologies
Frequency 50 Hz
Voltage 220/230 V AC
Power 1.3 KW
Max Temperature 350 deg C
Flask Size 30-100 ml



Precision Nitrogen Analysis

Achieve reliable results for nitrogen determination with the Kjeldahl Distillation Unit. Engineered for lab-scale use, the setup combines high-precision manual controls and analog display, ensuring accuracy and reproducibility. Adjustable heating and efficient distillation enable consistent performance, streamlining your analytical workflows.


Built for Safety and Efficiency

Safety and convenience are fundamental to this distillation unit. The equipment is fitted with over-heating protection, a fully insulated cabinet, and corrosion-resistant, powder-coated mild steel. The borosilicate glass condenser and flasks guarantee chemical stability and temperature resistance up to 300C, supporting long-term operational integrity.


Versatile Configurations for Every Lab

Whether your laboratory requires a single or multiple distillation units, this instrument can be configured accordingly. Supporting capacities from 500 ml to 1000 ml and available with or without a fume removal system, it adapts seamlessly to the varying needs of educational, analytical, and research institutions. Flexible mounting and high-quality materials ensure reliable support for your experiments.

FAQ's of Kjeldahl Distillation:


Q: How does the Kjeldahl Distillation Unit function in nitrogen analysis?

A: The Kjeldahl Distillation Unit facilitates the digestion and distillation of samples to release and measure nitrogen content, following the Kjeldahl method. It uses efficient heating mantles, glass condensers, and an analog display for precise manual control, ensuring accurate laboratory results.

Q: What safety features are included with this distillation apparatus?

A: Safety is prioritized with an insulated cabinet, over-heating protection, and robust construction from mild steel with a powder-coated finish. The use of borosilicate glass parts and optional fume evacuation systems further enhance operator safety and reliability.

Q: When should I use a Kjeldahl Distillation Unit in my laboratory workflow?

A: The unit is ideal for use whenever precise nitrogen content analysis is required, commonly in chemical, agricultural, educational, and food testing labs. Its consistent results and scalability from 1 to 6 units make it suitable for both routine and research-based experiments.

Q: Where can this equipment be effectively utilized?

A: This distillation unit is well-suited for educational institutions, analytical labs, and research facilities requiring accurate nitrogen estimation. Its modular design and robust materials make it practical for laboratories in India and globally.

Q: What is the process of operating the Kjeldahl Distillation Unit?

A: Operation involves loading the sample into a borosilicate glass flask, applying heat via a fixed or replaceable mantle, condensing the distillate with a high-efficiency condenser, and collecting it for titration using a 50 ml burette. Manual controls and safety features support user-friendly operation.

Q: Why choose this Kjeldahl unit over other distillation systems?

A: This unit offers high accuracy, corrosion-resistant materials, easy maintenance, and multiple configuration options. Its adaptable design, temperature resistance, and integrated safety ensure both performance and simplified laboratory management.

Q: How can users benefit from features like adjustable heating and manual control?

A: Adjustable heating allows precise temperature management, optimizing distillation for diverse sample types. Manual control paired with analog display provides hands-on precision, supporting detailed analytical work and enhancing data reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware And Equipments Category

Biological Safety Cabinet (As Per Class Ii)

Biological Safety Cabinet (As Per Class Ii)

Application : Laboratory, Research, Medical, Pharmaceutical

Power : 220V/50Hz

Features : HEPA Filter, UV Light, Fluorescent Lamp, Audible Alarm, Motorized Shutter

Equipment Materials : Stainless Steel, Powder Coated Mild Steel

Dimension (L*W*H) : 1200mm x 750mm x 2100mm

Material : Stainless Steel Grade 304

Mantle Type Soxhlet Extraction Unit

Mantle Type Soxhlet Extraction Unit

Application : Laboratory solvent extraction for oils, fats, pesticides, and other organic compounds from solid samples

Power : 600W to 1500W (varies with unit/batch size)

Features : Multiple mantle units, corrosionresistant body, efficient and uniform heating, individual temperature control, easy glassware access, high chemical resistance

Equipment Materials : Mild Steel Body with Powder Coated Finish and Ceramic Fiber Insulated Heating Mantle

Dimension (L*W*H) : 450 x 250 x 300 mm (for standard 3/6 unit models)

Material : Mild Steel (Body) & Borosilicate Glassware (Flask/Condenser)

Anatomical Models

Anatomical Models

Application : Educational purpose medical training anatomy demonstration

Power : None required

Features : Detachable parts realistic texture labeled organs

Equipment Materials : Plastic Polymer

Dimension (L*W*H) : Standard anatomical model dimensions

Material : Durable plastic

Bunsen Burner Needle Valve

Bunsen Burner Needle Valve

Application : Laboratory heating and flame generation

Power : Nonelectric

Features : Adjustable flame; Stable base; Precision needle valve control

Equipment Materials : Brass body with nickelplated finish

Dimension (L*W*H) : Approx. 150 mm 60 mm 40 mm

Material : Brass



Back to top