MICHEALSON INTERFEROMETER
MICHEALSON INTERFEROMETER

MICHEALSON INTERFEROMETER

MICHEALSON INTERFEROMETER Specification

  • Type
  • Optical Interferometer
  • Material
  • Aluminium, Glass, Steel
  • Size
  • Standard Laboratory Model
  • Input Voltage
  • 230V AC, 50Hz
  • Color
  • Metallic Grey
  • Dimension (L*W*H)
  • 400 mm x 250 mm x 350 mm
  • Capacity
  • Single Beam/ Dual Beam
  • Noise Level
  • Silent Operation
  • Applications
  • Precise measurement of wavelength, refractive index, and surface flatness
  • Weight
  • Approx. 12 kg
  • Optical Components
  • Lenses, beam splitter, mirrors, and compensator plate included
  • Mirror Adjustment
  • Fine and coarse adjustment screws for precise alignment
  • Observation Tube
  • Fitted observation tube with focusing arrangement
  • Base
  • Rigid heavy base for stability
  • Scale Reading
  • Vernier scale with 0.01 mm accuracy
  • Travel Range
  • Up to 10 mm movement for movable mirror
  • Packaging
  • Supplied with dust cover and instruction manual
  • Compatibility
  • Suitable for monochromatic and white light experiments
  • Assembly
  • Pre-assembled and ready for demonstration
 
 

About MICHEALSON INTERFEROMETER



The MICHEALSON INTERFEROMETER is a must-have, first-class optical instrument designed for ace performance in scientific research and academic laboratories. Featuring a robust build with a rigid heavy base, this cost-effective model comes pre-assembled and ready for demonstration, saving you valuable setup time. Exceptional optical componentsincluding lenses, a beam splitter, precision mirrors, and a compensator plateensure top-tier results. With fine and coarse mirror adjustments, accurate vernier scale readings, and silent operation, it stands out as the ultimate choice for precise measurement and experimental reliability.

Advanced Scientific Applications: Measure with Precision

The MICHEALSON INTERFEROMETER is ideal for precise wavelength determination, refractive index calculations, and analysis of surface flatnessmaking it ace for physics labs, material science centers, and educational demonstrations. It excels with both monochromatic and white light sources, providing versatile compatibility for a wide range of optical experiments. Its robust construction and high accuracy ensure first-class results in any laboratory or research environment, solidifying its reputation as an exceptional tool for scientific discovery.


Reliable Delivery and Secure Export Handling

All units are expertly packaged with dust cover and instruction manual for safe drop-off and secure shipment. We provide prompt handover to buyers across India, as well as efficient export market solutions for global destinations. Delivery times are minimized to ensure swift access to this first-class optical instrumentready to ace your experiments right out of the box. Our domestic support guarantees dependable service and satisfaction for every customer, ensuring your investment is both cost-effective and seamless.


FAQs of MICHEALSON INTERFEROMETER:


Q: How is the MICHEALSON INTERFEROMETER assembled and delivered?

A: The interferometer comes pre-assembled for immediate use. It is securely packed with a dust cover, instruction manual, and is ready for quick drop-off or handover on order completion.

Q: What applications can the MICHEALSON INTERFEROMETER be used for?

A: This device is ace for measuring light wavelengths, refractive indices, and surface flatness, suitable for monochromatic and white light experiments in both educational and research settings.

Q: What makes the MICHEALSON INTERFEROMETER a cost-effective purchase?

A: Its robust build, pre-assembled structure, reliable accuracy, and inclusion of all key optical components mean it provides exceptional long-term value and savings for labs and institutions.

Q: Where can the MICHEALSON INTERFEROMETER be used effectively?

A: It is ideal for use in physics labs, universities, material science research centers, and other educational or industrial environments where precise optical measurement is essential.

Q: What is the process for adjusting mirror alignment in this model?

A: The instrument features both fine and coarse adjustment screws, allowing precise and smooth alignment of the mirrors to maximize experimental accuracy and repeatability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

measurement of efficiency of single phase

measurement of efficiency of single phase

Size : Standard Laboratory Size

Dimension (L*W*H) : 340 mm x 220 mm x 250 mm

Input Voltage : 230 V AC, 50 Hz

Color : Grey/Blue

Material : Mild Steel, Brass, Bakelite, Copper Winding

Type : Other, Wattmeter Method Test Apparatus

THREE PHASE VOLTAGE SOURCE IGBT INVERTER USING PWM TECHINQUES

THREE PHASE VOLTAGE SOURCE IGBT INVERTER USING PWM TECHINQUES

Size : Standard Laboratory Module

Dimension (L*W*H) : 340 mm x 220 mm x 105 mm

Input Voltage : 415V AC, Three Phase

Color : Blue/Grey

Material : Industrial Grade Electronic Components

Type : Other, Three Phase Voltage Source Inverter

HE-NE LASER (RED)

HE-NE LASER (RED)

Size : Standard laboratory size (Typically 14 mm diameter, length varies)

Dimension (L*W*H) : Approx. 330 mm x 40 mm x 40 mm

Input Voltage : 110V / 220V AC or DC (via power supply unit)

Color : Red

Material : Glass tube with mirror ends and gas fill (HeliumNeon)

Type : Other, HENE Laser (Red)

CRYSTAL OSCILLATOR TRAINER

CRYSTAL OSCILLATOR TRAINER

Size : Standard Laboratory Size

Dimension (L*W*H) : 285 mm x 180 mm x 60 mm

Input Voltage : 230V AC, 50 Hz

Color : Blue Panel with White Base

Material : High Grade PCB, Electronic Components

Type : Other, Crystal Oscillator Trainer



Back to top