MICHELSON INTEROMETER MODEL SMI-25
MICHELSON INTEROMETER MODEL SMI-25

MICHELSON INTEROMETER MODEL SMI-25

MICHELSON INTEROMETER MODEL SMI-25 Specification

  • Type
  • Optical Interferometer
  • Material
  • Heavy cast iron base with metal components and high-quality optical glass mirrors
  • Size
  • Standard Laboratory Size
  • Color
  • Grey/Black with chromium-plated fittings
  • Dimension (L*W*H)
  • 425 mm x 220 mm x 330 mm (Approx)
  • Noise Level
  • Silent Operation
  • Base
  • Heavy, stable, vibration-damped cast iron base
  • Accessories Included
  • Beam splitter, two plane mirrors, adjustable mirror mount, user manual
  • Model
  • SMI-25
  • Micrometer Screw Precision
  • 0.01 mm/minimum graduation
  • Applications
  • Measurement of wavelength, refractive index determination, calibration, and optics education
  • Support Components
  • Chrome-plated pillars and metal holders
  • Mirror Mount Adjustments
  • Precision screws for fine adjustments and pitch-rotation controls
  • Beam Splitter
  • Optical glass plate
  • Working Principle
  • Michelson Interference
  • Number of Adjustable Arms
  • Two (one fixed, one movable)
  • Movable Mirror Travel
  • 25 mm (with micrometer screw) with vernier scale for precision
  • Spectral Use
  • Sodium or other monochromatic light source applicable
  • Weight
  • Approx 10 kg
  • Optical Flatness
  • Lambda/4 or better
 
 

About MICHELSON INTEROMETER MODEL SMI-25



Discover the monumental MICHELSON INTEROMETER MODEL SMI-25-a featured, best-selling optical interferometer renowned for its sought-after precision. Equipped with heroic precision screws and pitch-rotation controls, this top-tier model ensures fine adjustments with ease. Its stable, vibration-damped cast iron base and lambda/4 optical flatness cater to advanced measurements, including wavelength determination and refractive index calibration. Ideal for optics education and laboratory research, this robust instrument includes all necessary accessories and excels in performance and durability. Trusted nationwide by leading distributors, exporters, and researchers.

Exceptional Applications & Features

The MICHELSON INTEROMETER MODEL SMI-25 is expertly used for measuring wavelengths, refractive index determination, calibration, and in optics education. Key features include two adjustable arms, a movable mirror with micrometer screw for heroic fine-tuning, and a heavy-duty cast iron base ensuring stability. It supports both sodium and other monochromatic light sources, making it a sought-after asset in laboratories.


Main Market and Delivery Assurance

Serving the Indian domestic market and prominent international exporters, the SMI-25 is promptly delivered via secure shipping. With an efficient delivery schedule and reasonable charges, distributors and suppliers enjoy hassle-free logistics. Our commitment to secure packaging and responsible handling ensures the interferometer arrives safely and on time, ready for impactful scientific work.


FAQ's of MICHELSON INTEROMETER MODEL SMI-25:


Q: How does the MICHELSON INTEROMETER MODEL SMI-25 ensure precise measurements?

A: The SMI-25 is equipped with precision screws, micrometer adjustments to 0.01 mm, and a vernier scale. Its stable, vibration-damped cast iron base and lambda/4 optical flatness further enhance measurement accuracy.

Q: What applications can the SMI-25 model be used for?

A: It is widely used for measuring the wavelength of light, determining refractive index, calibration procedures, and as a teaching tool in optics education.

Q: Where can I purchase the SMI-25 Interometer?

A: The SMI-25 is available through authorized distributors, exporters, manufacturers, suppliers, and traders across India and in main export markets.

Q: What is the process for using the interferometer with sodium light?

A: Simply set up the included beam splitter and mirrors, align the sodium light source, make precise mirror adjustments, and observe the interference patterns for accurate wavelength measurement.

Q: What are the benefits of the heavy cast iron base on the SMI-25?

A: The robust cast iron base mitigates vibrations, providing a solid, stable platform, which is critical for precise optical measurements and repeatable results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

YOUNG MODULUS OF A WIRE BY OPTICAL LEVER METHOD

YOUNG MODULUS OF A WIRE BY OPTICAL LEVER METHOD

Color : Metallic Grey with Brass Components

Capacity : Suitable for single wire specimens, max load up to 10kg

Material : Mild Steel, Polished Brass, Glass (Mirror), Aluminium (Scale)

Noise Level : Silent operation

Size : Standard laboratory size

Dimension (L*W*H) : 60 cm x 20 cm x 25 cm (approx.)

PLC TRAINER (ALLEN BRADLEY 14-10 I/O)

PLC TRAINER (ALLEN BRADLEY 14-10 I/O)

Color : GreyWhite with Label Markings

Capacity : 14 Input / 10 Output Digital Channels

Material : Mild Steel Body with Polycarbonate Front Panel

Noise Level : Silent Operation

Size : Compact Desktop

Dimension (L*W*H) : 500 mm x 400 mm x 150 mm

FREQUENCY METERS FOR X-BAND BEND

FREQUENCY METERS FOR X-BAND BEND

Color : Silver / Metallic

Capacity : Detects Frequency Range as Per XBand

Material : Aluminum Alloy, Precision Components

Noise Level : Negligible / Passive Operation

Size : Standard XBand Waveguide Size

Dimension (L*W*H) : Approx. 150mm x 80mm x 50mm

BATTERY ELIMINATOR D.C AC & DC

BATTERY ELIMINATOR D.C AC & DC

Color : Black/Blue (as available)

Capacity : 1A, 2A, 5A (models available)

Material : High quality ABS plastic & metal components

Noise Level : Silent Operation

Size : Compact

Dimension (L*W*H) : Approx. 140 mm x 90 mm x 70 mm