MICHELSON INTEROMETER MODEL SMI-25
MICHELSON INTEROMETER MODEL SMI-25

MICHELSON INTEROMETER MODEL SMI-25

MICHELSON INTEROMETER MODEL SMI-25 Specification

  • Type
  • Optical Interferometer
  • Material
  • Heavy cast iron base with metal components and high-quality optical glass mirrors
  • Size
  • Standard Laboratory Size
  • Color
  • Grey/Black with chromium-plated fittings
  • Dimension (L*W*H)
  • 425 mm x 220 mm x 330 mm (Approx)
  • Noise Level
  • Silent Operation
  • Mirror Mount Adjustments
  • Precision screws for fine adjustments and pitch-rotation controls
  • Applications
  • Measurement of wavelength, refractive index determination, calibration, and optics education
  • Base
  • Heavy, stable, vibration-damped cast iron base
  • Optical Flatness
  • Lambda/4 or better
  • Model
  • SMI-25
  • Spectral Use
  • Sodium or other monochromatic light source applicable
  • Micrometer Screw Precision
  • 0.01 mm/minimum graduation
  • Accessories Included
  • Beam splitter, two plane mirrors, adjustable mirror mount, user manual
  • Number of Adjustable Arms
  • Two (one fixed, one movable)
  • Movable Mirror Travel
  • 25 mm (with micrometer screw) with vernier scale for precision
  • Support Components
  • Chrome-plated pillars and metal holders
  • Working Principle
  • Michelson Interference
  • Beam Splitter
  • Optical glass plate
  • Weight
  • Approx 10 kg
 
 

About MICHELSON INTEROMETER MODEL SMI-25



Discover the monumental MICHELSON INTEROMETER MODEL SMI-25-a featured, best-selling optical interferometer renowned for its sought-after precision. Equipped with heroic precision screws and pitch-rotation controls, this top-tier model ensures fine adjustments with ease. Its stable, vibration-damped cast iron base and lambda/4 optical flatness cater to advanced measurements, including wavelength determination and refractive index calibration. Ideal for optics education and laboratory research, this robust instrument includes all necessary accessories and excels in performance and durability. Trusted nationwide by leading distributors, exporters, and researchers.

Exceptional Applications & Features

The MICHELSON INTEROMETER MODEL SMI-25 is expertly used for measuring wavelengths, refractive index determination, calibration, and in optics education. Key features include two adjustable arms, a movable mirror with micrometer screw for heroic fine-tuning, and a heavy-duty cast iron base ensuring stability. It supports both sodium and other monochromatic light sources, making it a sought-after asset in laboratories.


Main Market and Delivery Assurance

Serving the Indian domestic market and prominent international exporters, the SMI-25 is promptly delivered via secure shipping. With an efficient delivery schedule and reasonable charges, distributors and suppliers enjoy hassle-free logistics. Our commitment to secure packaging and responsible handling ensures the interferometer arrives safely and on time, ready for impactful scientific work.


FAQ's of MICHELSON INTEROMETER MODEL SMI-25:


Q: How does the MICHELSON INTEROMETER MODEL SMI-25 ensure precise measurements?

A: The SMI-25 is equipped with precision screws, micrometer adjustments to 0.01 mm, and a vernier scale. Its stable, vibration-damped cast iron base and lambda/4 optical flatness further enhance measurement accuracy.

Q: What applications can the SMI-25 model be used for?

A: It is widely used for measuring the wavelength of light, determining refractive index, calibration procedures, and as a teaching tool in optics education.

Q: Where can I purchase the SMI-25 Interometer?

A: The SMI-25 is available through authorized distributors, exporters, manufacturers, suppliers, and traders across India and in main export markets.

Q: What is the process for using the interferometer with sodium light?

A: Simply set up the included beam splitter and mirrors, align the sodium light source, make precise mirror adjustments, and observe the interference patterns for accurate wavelength measurement.

Q: What are the benefits of the heavy cast iron base on the SMI-25?

A: The robust cast iron base mitigates vibrations, providing a solid, stable platform, which is critical for precise optical measurements and repeatable results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

VELOCITY OF SOUND IN AIR BY RESONANCE COLUMN APPARATUS

VELOCITY OF SOUND IN AIR BY RESONANCE COLUMN APPARATUS

Type : Other, Resonance Column Apparatus

Capacity : Single experimental unit

Material : Glass column, metallic reservoir, Rubber fittings

Color : Transparent (column) with blue/grey metallic parts

Dimension (L*W*H) : Approx. 100 cm x 10 cm x 10 cm

Size : Column Length 1 meter

PLC TRAINER (SIEMENS (S7-200)

PLC TRAINER (SIEMENS (S7-200)

Type : Other, PLC Trainer Kit (Siemens S7200)

Capacity : Multiple I/O Simulation Capability

Material : Powder Coated Metal Panel with Acrylic and ABS Components

Color : White/Blue

Dimension (L*W*H) : Approx. 600 mm x 400 mm x 200 mm

Size : Standard Laboratory Benchtop

TO FIND THE RESISTANCE OF GIVEN WIRE USING METER BRIDGE EXPERIMENT (DIGITAL)

TO FIND THE RESISTANCE OF GIVEN WIRE USING METER BRIDGE EXPERIMENT (DIGITAL)

Type : Other, Digital Meter Bridge Experimental Apparatus

Capacity : Suitable for Laboratory Experiments with up to 10A Current

Material : Bakelite/Brass/Aluminium/Plastic (Noncorrosive, Educational Grade)

Color : White/Blue (as per model availability)

Dimension (L*W*H) : Approx. 110cm x 15cm x 12cm

Size : Standard Laboratory Size

STAND FOR MERCURY LAMP

STAND FOR MERCURY LAMP

Type : Other, Mercury Lamp Stand

Capacity : Supports up to 400W Lamp

Material : Mild Steel

Color : White

Dimension (L*W*H) : Approx. 18 inch x 14 inch x 36 inch

Size : Standard



Back to top