TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT
TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT

TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT

TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT Specification

  • Type
  • Physics Laboratory Apparatus
  • Material
  • Optically processed glass, stainless steel, and anodized aluminum
  • Size
  • Standard laboratory size
  • Input Voltage
  • 220 V AC (for sodium lamp)
  • Color
  • Spectrometer: Silver/Grey, Sodium Lamp: Yellow/Metallic
  • Dimension (L*W*H)
  • Spectrometer: 32 x 20 x 28 cm (approx); Sodium Lamp: 25 x 10 x 15 cm (approx)
  • Capacity
  • Designed for single-user or group demonstration
  • Noise Level
  • Silent operation
  • Wavelength Used
  • 589 nm (Sodium D-line)
  • Calibration Method
  • Adjustable and calibrated angular measurement
  • Focusing Mechanism
  • Manual precision adjustment
  • Sample Type
  • Optical calcite crystal (provided/compatible up to 25-38 mm)
  • Accessories Included
  • Sodium lamp unit, prism, lens, screws, instruction manual
  • Application
  • Determining refractive index of calcite crystal
  • Light Source
  • Sodium vapor lamp
  • Reading Accuracy
  • Up to 0.01 degree
  • Educational Use
  • Ideal for college, university, and research laboratories
  • Spectrometer Features
  • Collimator, telescope with fine adjustment, graduated scale, vernier scale
  • Main Components
  • Spectrometer, Calcite Prism, Sodium Lamp, Prism Holder
  • Operating Temperature
  • Room temperature (15C to 35C recommended)
  • Prism Size
  • Typically 30 mm or 32 mm edges (may vary)
 
 

About TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT



Grab the Champion choice for advanced physics education with our renowned apparatus, specially designed to determine the refractive index of calcite crystals using a spectrometer and sodium light. Experience cost-effective precision, promoted to enlighten students and researchers in colleges, universities, and institutes across India. The set boasts a spectrometer with fine adjustment, a calibrated graduated scale, and includes essential accessories like an optically processed calcite prism and a sodium lamp unit. Enjoy reliable, silent operation and robust materials to enhance any laboratorys curriculum and experiments.

Application, Features & Commercial Uses

Ideal for college and research labs, this apparatus is an enlightened solution for optical property studies in geology, crystallography, and material analysis. The spectrometers accuracy, enhanced by renowned manual focusing and calibrated measurements, ensures reliable experimental outcomes. Commercially, its promoted among educational suppliers, distributors, and exporters for advanced demonstration and student training in Indiaa cost-effective tool for research, teaching, and optical calibration of calcite crystals.


Packaging, Delivery & Payment Terms

Proposal amount and lowest price options are available, offering competitive deals for bulk orders. Each kit is securely packaged to protect all components, with standard FOB port shipping from India. Items are shipped promptly upon confirmation of payment terms such as TT or LC, ensuring swift delivery. Our distributors, suppliers, and traders prioritize safe, on-time shipment to guarantee your apparatus arrives in optimal condition, ready for installation and use.


FAQs of TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT:


Q: How is the refractive index of calcite determined using this apparatus?

A: The refractive index is measured by passing sodium light through the calcite prism placed on the spectrometer. By adjusting the collimator and telescope and precisely recording angular deviations, users can calculate the refractive index using the provided wavelengths and angular scales.

Q: What is the main benefit of using a sodium vapor lamp with the spectrometer?

A: The sodium vapor lamp emits monochromatic light at 589 nm, providing a stable and precise wavelength (D-line) for accurate optical measurements. This significantly enhances the reliability of refractive index calculations for calcite crystals.

Q: When is this apparatus ideal for use in educational settings?

A: It is best utilized during laboratory courses in physics, optics, or material science, and for research projects focused on crystallography and mineral analysis in colleges and universities.

Q: Where is this product distributed and exported from?

A: The apparatus is manufactured, supplied, and exported by renowned distributors and traders based in India, with shipment available to various global destinations.

Q: What components and accessories are included in the package?

A: The package includes a precision spectrometer, calcite prism, sodium lamp unit, prism holder, lens, screws, and a detailed instruction manual, providing everything needed for immediate setup and experimentation.

Q: How can users ensure accurate readings during experiments?

A: Accurate readings are achieved by calibrating the spectrometers angular measurements, using the vernier and graduated scales, and ensuring precise manual focusing on the calcite prism while conducting each assessment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

AF-RF OSCILLATOR TRAINER

AF-RF OSCILLATOR TRAINER

Noise Level : Low noise operation, shielded for interference

Dimension (L*W*H) : 350 mm x 225 mm x 125 mm

Type : Other, AFRF Oscillator Trainer

Size : Standard laboratory trainer unit

Material : Metal and highgrade PCB components

Color : Grey

THREE PHASE VOLTAGE SOURCE IGBT INVERTER USING PWM TECHINQUES

THREE PHASE VOLTAGE SOURCE IGBT INVERTER USING PWM TECHINQUES

Noise Level : Low (<60 dB)

Dimension (L*W*H) : 340 mm x 220 mm x 105 mm

Type : Other, Three Phase Voltage Source Inverter

Size : Standard Laboratory Module

Material : Industrial Grade Electronic Components

Color : Blue/Grey

STATIC AND DYNAMIC CHARACTERISTICS OF IGBT AND MOSFET

STATIC AND DYNAMIC CHARACTERISTICS OF IGBT AND MOSFET

Noise Level : Silent Operation

Dimension (L*W*H) : 340 mm x 250 mm x 120 mm

Type : Other, Static and Dynamic Characteristics Analyzer for IGBT and MOSFET

Size : Standard Laboratory Module

Material : Electronics Grade Components, High Quality PCB

Color : Blue and White

NEELDLE STAND

NEELDLE STAND

Noise Level : Silent Operation

Dimension (L*W*H) : 26 cm x 8 cm x 12 cm

Type : Other, Needle Stand

Size : Standard

Material : Highquality Aluminum & Stainless Steel

Color : Silver



Back to top