TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT
TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT

TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT

TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT Specification

  • Type
  • Physics Laboratory Apparatus
  • Material
  • Optically processed glass, stainless steel, and anodized aluminum
  • Size
  • Standard laboratory size
  • Input Voltage
  • 220 V AC (for sodium lamp)
  • Color
  • Spectrometer: Silver/Grey, Sodium Lamp: Yellow/Metallic
  • Dimension (L*W*H)
  • Spectrometer: 32 x 20 x 28 cm (approx); Sodium Lamp: 25 x 10 x 15 cm (approx)
  • Capacity
  • Designed for single-user or group demonstration
  • Noise Level
  • Silent operation
  • Operating Temperature
  • Room temperature (15C to 35C recommended)
  • Wavelength Used
  • 589 nm (Sodium D-line)
  • Calibration Method
  • Adjustable and calibrated angular measurement
  • Sample Type
  • Optical calcite crystal (provided/compatible up to 25-38 mm)
  • Application
  • Determining refractive index of calcite crystal
  • Spectrometer Features
  • Collimator, telescope with fine adjustment, graduated scale, vernier scale
  • Educational Use
  • Ideal for college, university, and research laboratories
  • Accessories Included
  • Sodium lamp unit, prism, lens, screws, instruction manual
  • Focusing Mechanism
  • Manual precision adjustment
  • Reading Accuracy
  • Up to 0.01 degree
  • Main Components
  • Spectrometer, Calcite Prism, Sodium Lamp, Prism Holder
  • Light Source
  • Sodium vapor lamp
  • Prism Size
  • Typically 30 mm or 32 mm edges (may vary)
 
 

About TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT



Grab the Champion choice for advanced physics education with our renowned apparatus, specially designed to determine the refractive index of calcite crystals using a spectrometer and sodium light. Experience cost-effective precision, promoted to enlighten students and researchers in colleges, universities, and institutes across India. The set boasts a spectrometer with fine adjustment, a calibrated graduated scale, and includes essential accessories like an optically processed calcite prism and a sodium lamp unit. Enjoy reliable, silent operation and robust materials to enhance any laboratorys curriculum and experiments.

Application, Features & Commercial Uses

Ideal for college and research labs, this apparatus is an enlightened solution for optical property studies in geology, crystallography, and material analysis. The spectrometers accuracy, enhanced by renowned manual focusing and calibrated measurements, ensures reliable experimental outcomes. Commercially, its promoted among educational suppliers, distributors, and exporters for advanced demonstration and student training in Indiaa cost-effective tool for research, teaching, and optical calibration of calcite crystals.


Packaging, Delivery & Payment Terms

Proposal amount and lowest price options are available, offering competitive deals for bulk orders. Each kit is securely packaged to protect all components, with standard FOB port shipping from India. Items are shipped promptly upon confirmation of payment terms such as TT or LC, ensuring swift delivery. Our distributors, suppliers, and traders prioritize safe, on-time shipment to guarantee your apparatus arrives in optimal condition, ready for installation and use.


FAQs of TO DETERMINE THE REFRACTIVE INDEX OF THE CALCITE USING SPECTROMETER AND SODIUM LIGHT:


Q: How is the refractive index of calcite determined using this apparatus?

A: The refractive index is measured by passing sodium light through the calcite prism placed on the spectrometer. By adjusting the collimator and telescope and precisely recording angular deviations, users can calculate the refractive index using the provided wavelengths and angular scales.

Q: What is the main benefit of using a sodium vapor lamp with the spectrometer?

A: The sodium vapor lamp emits monochromatic light at 589 nm, providing a stable and precise wavelength (D-line) for accurate optical measurements. This significantly enhances the reliability of refractive index calculations for calcite crystals.

Q: When is this apparatus ideal for use in educational settings?

A: It is best utilized during laboratory courses in physics, optics, or material science, and for research projects focused on crystallography and mineral analysis in colleges and universities.

Q: Where is this product distributed and exported from?

A: The apparatus is manufactured, supplied, and exported by renowned distributors and traders based in India, with shipment available to various global destinations.

Q: What components and accessories are included in the package?

A: The package includes a precision spectrometer, calcite prism, sodium lamp unit, prism holder, lens, screws, and a detailed instruction manual, providing everything needed for immediate setup and experimentation.

Q: How can users ensure accurate readings during experiments?

A: Accurate readings are achieved by calibrating the spectrometers angular measurements, using the vernier and graduated scales, and ensuring precise manual focusing on the calcite prism while conducting each assessment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

1, 2 AND 4 QUADRANT CHOPPER TRAINER

1, 2 AND 4 QUADRANT CHOPPER TRAINER

Color : Light Grey with printed front panel

Dimension (L*W*H) : Approx. 400 mm x 300 mm x 150 mm

Type : Other, 1, 2 and 4 Quadrant Chopper Trainer

Capacity : Up to 1A load current at output

Size : Bench Top Trainer

Material : Highgrade mild steel body with powder coating and acrylic panel

COSINE FIRING TECHNIQUE CIRCUIT TRAINER

COSINE FIRING TECHNIQUE CIRCUIT TRAINER

Color : Blue & White

Dimension (L*W*H) : 260 mm x 200 mm x 75 mm

Type : Other, Electronic Circuit Trainer

Capacity : Single Unit

Size : Standard Laboratory Size

Material : Highgrade PCB, ABS Body

TO DETERMINE THE REFRACTIVE INDEX OF LIQUID BY TOTAL INTERNAL REFLECTION USING WOLLASTONS AIR-FILM.

TO DETERMINE THE REFRACTIVE INDEX OF LIQUID BY TOTAL INTERNAL REFLECTION USING WOLLASTONS AIR-FILM.

Color : Transparent glass with metallic frame

Dimension (L*W*H) : Approx. 25 cm x 15 cm x 10 cm

Type : Other, Optical Physics Laboratory Apparatus

Capacity : Designed for single experiment usage

Size : Standard laboratory size set

Material : Polished glass and metal

REGULATED POWER SUPPLY

REGULATED POWER SUPPLY

Color : Grey with black panel

Dimension (L*W*H) : Approx. 260mm x 185mm x 140mm

Type : Other, Regulated Power Supply

Capacity : 030V DC output, up to 2A

Size : Standard laboratory size

Material : Steel chassis with electronic components



Back to top