VERIFICATION OF FRESNELS EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES EXPRIMENTAL SETUP
VERIFICATION OF FRESNELS EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES EXPRIMENTAL SETUP

VERIFICATION OF FRESNELS EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES EXPRIMENTAL SETUP

VERIFICATION OF FRESNELS EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES EXPRIMENTAL SETUP Specification

  • Type
  • Experimental Setup for Optical Physics
  • Material
  • Optical Grade Glass, Aluminum, Steel, Electronic Components
  • Size
  • Standard Laboratory Bench-top
  • Input Voltage
  • 220 V AC, 50 Hz
  • Color
  • Grey and Black Finish
  • Dimension (L*W*H)
  • Approx. 500 mm 300 mm 350 mm
  • Capacity
  • Single experimental unit
  • Noise Level
  • Negligible
  • Weight
  • Approx. 12 kg
  • Polarizer
  • Rotatable Polarizing Grid for s- and p-polarization studies
  • Detector Type
  • Movable Microwave Receiver with Horn Antenna and Detector
  • Accessories Included
  • Complete leads, power cords, manual, and mounting hardware
  • Wave Source Type
  • Microwave Generator with Horn Antenna
  • Compliance
  • Meets standard university/college curriculum requirements for physics laboratories
  • Power Consumption
  • Less than 30 W
  • Protractor Accuracy
  • Angular scale with 1 precision
  • Experiment Purpose
  • Verification of Fresnels Equations for Reflection of Electromagnetic Waves
  • Environment
  • Designed for indoor laboratory use
  • Mounting
  • Rigid base with adjustable arms for incidence angle variation
  • Calibration
  • Pre-calibrated with certificate included
  • Reflector Material
  • High Conductivity Polished Aluminum Plate
  • Frequency Range
  • 812 GHz (X-band microwaves)
  • Display Type
  • Digital panel meter for detected intensity measurement
 
 

About VERIFICATION OF FRESNELS EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES EXPRIMENTAL SETUP



Explore a grand and masterful experimental setup: the VERIFICATION OF FRESNEL'S EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES. Engineered with a first-string microwave generator, this apparatus covers the 8-12 GHz range and utilizes high conductivity polished aluminum for reliable reflectivity. Its digital panel ensures precise readings, supported by a pre-calibrated certificate for immediate laboratory application. Enjoy the lowest price and limited stock availability from trusted distributors across India. Designed to meet optical physics needs, this single-unit system is perfect for academic environments demanding accuracy and durability.

Commercial Utility and Advanced Features

This experimental setup offers versatile usage for university, college, and research laboratories. Featuring a robust construction with optical grade glass and premium metal components, it facilitates advanced studies on electromagnetic reflection phenomena. The unit comes fully equipped with digital display, rotatable polarizer, and movable receiver, making it ideal for optical physics, applied physics, and engineering courses. Instructors and researchers can rely on its rigid mounting, negligible noise level, and comprehensive accessories for seamless operation.


Shipping, Sample, and Certifications

Units are promptly dispatched via express shipping from designated FOB ports across India, with flexible drop-off options available. Sample policies allow evaluation prior to bulk procurement, ensuring full confidence. Every system arrives with international certification documents, calibration certificates, and adheres to standard laboratory compliances. Manufacturers and suppliers guarantee careful handling for secure delivery and rapid installation. Trust accredited exporters for quality assurance and seamless laboratory integration.


FAQ's of VERIFICATION OF FRESNELaS EQUATIONS FOR REFLECTION OF ELECTROMAGNETIC WAVES EXPRIMENTAL SETUP:


Q: How does the experimental setup verify Fresnel's equations for electromagnetic wave reflection?

A: The setup uses a microwave generator and receiver to measure reflection intensities at various angles and polarizations, allowing users to experimentally confirm Fresnel's equations.

Q: What is included with the VERIFICATION OF FRESNEL'S EQUATIONS setup?

A: It comes with a calibrated experimental unit, digital panel meter, all necessary leads, power cords, rotatable polarizing grid, mounting hardware, and a comprehensive manual.

Q: When can I expect delivery after placing an order for this setup?

A: Express shipping ensures prompt dispatch, typically within a few working days, with drop-off and FOB port pick-up available for convenience.

Q: Where is the equipment manufactured and distributed?

A: The setup is manufactured, supplied, and exported by verified distributors across India, meeting international standards for academic use.

Q: What is the process for calibration and certification?

A: Each unit is pre-calibrated and arrives with an official calibration certificate, guaranteeing measurement accuracy and compliance with laboratory requirements.

Q: How can students and researchers benefit from using this apparatus?

A: By using this setup, users gain hands-on experience in verifying optical physics principles, enhancing practical learning and supporting advanced research projects.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SPEED CONTROL OF SEPARATELY EXCITED DC SERIES MOTOR USING SINGLE PHASE HALF WAVE BRIDGE CONTROLLED BRIDGE CONVERTER TRAINER

SPEED CONTROL OF SEPARATELY EXCITED DC SERIES MOTOR USING SINGLE PHASE HALF WAVE BRIDGE CONTROLLED BRIDGE CONVERTER TRAINER

Color : Grey & Blue

Input Voltage : 230V AC, 50Hz

Noise Level : Low

Dimension (L*W*H) : Approx. 500 mm x 400 mm x 250 mm

Material : Mild Steel Sheet with Powder Coating & High Quality Components

Capacity : Suitable for 0.5 HP DC Series Motor

ZERO VOLTAGE SWITCHING USING SCR

ZERO VOLTAGE SWITCHING USING SCR

Color : Green/Blue PCB

Input Voltage : 230V AC

Noise Level : Silent operation

Dimension (L*W*H) : Approx. 100 mm x 75 mm x 25 mm

Material : PCB, Electronic Components

Capacity : Up to 1000W load control

AUDIO FREQUENCY FUNCTION GENERATOR 0-200KHz

AUDIO FREQUENCY FUNCTION GENERATOR 0-200KHz

Color : Grey

Input Voltage : 220V AC, 50 Hz

Noise Level : Low

Dimension (L*W*H) : 230 x 210 x 90 mm

Material : Highquality electronic components and metal casing

Capacity : Output Frequency Range: 0200 KHz

FOR THE MEASUREMENT OF THE TIME OF FALL OF A STEEL BALL TO DETERMINE THE VALUE OF G (G BY FREE BALL)

FOR THE MEASUREMENT OF THE TIME OF FALL OF A STEEL BALL TO DETERMINE THE VALUE OF G (G BY FREE BALL)

Color : Metallic Silver & Transparent

Input Voltage : 220V AC, 50Hz

Noise Level : Silent Operation

Dimension (L*W*H) : Approx. 80 cm x 15 cm x 15 cm

Material : Stainless Steel & Acrylic

Capacity : Single Ball Drop



Back to top