ZERO VOLTAGE SWITCHING USING SCR
ZERO VOLTAGE SWITCHING USING SCR

ZERO VOLTAGE SWITCHING USING SCR

ZERO VOLTAGE SWITCHING USING SCR Specification

  • Type
  • Zero Voltage Switching Using SCR
  • Material
  • PCB, Electronic Components
  • Size
  • Standard Module
  • Input Voltage
  • 230V AC
  • Color
  • Green/Blue PCB
  • Dimension (L*W*H)
  • Approx. 100 mm x 75 mm x 25 mm
  • Capacity
  • Up to 1000W load control
  • Noise Level
  • Silent operation
  • Response Time
  • <1 cycle of AC waveform
  • Triggering Mechanism
  • Opto-isolated gate drive
  • Mounting Type
  • Panel Mount / PCB Mount
  • Load Type
  • Resistive and Inductive loads
  • Switching Device
  • Silicon Controlled Rectifier (SCR)
  • Power Frequency
  • 50Hz-60Hz compatible
  • Control Method
  • Zero voltage detection and switching
  • Indication
  • LED status indicator
  • Compliance
  • RoHS Compliant
  • Output Voltage
  • Switching 230V AC loads
  • Operating Temperature Range
  • 0°C to 50°C
  • Protection Features
  • Snubber circuit provided
  • Applications
  • Industrial automation, AC power control, energy saving, lamp dimming, motor soft start
  • Storage Temperature Range
  • -20°C to 70°C
  • Isolation
  • Optical isolation between control and load
 
 
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

TO MEASURE THE DIAMETER OF A SMALL SPHERICAL CYLINDRICAL BODY WITH THE HELP OF VERNIER CALIPER

TO MEASURE THE DIAMETER OF A SMALL SPHERICAL CYLINDRICAL BODY WITH THE HELP OF VERNIER CALIPER

Noise Level : Silent Operation (Manual)

Type : Other, Measuring Instrument (Vernier Caliper Demonstration Set)

Material : Stainless Steel / Brass (Body); Plastic/Foam (Spherical & Cylindrical Objects)

Size : Standard Laboratory Size (Caliper Length: 150 mm)

Capacity : Measures up to 150mm (Caliper)

Input Voltage : Manual (No Power Required)

DOUBLE BEAM BALANCE

DOUBLE BEAM BALANCE

Noise Level : Silent Operation

Type : Other, Double Beam Balance

Material : Diecast metal base with steel beam and stainless steel platform

Size : Standard laboratory size

Capacity : Up to 2 kg

Input Voltage : Not Required (Mechanical Operation)

ARC POWER SUPPLY

ARC POWER SUPPLY

Noise Level : Low

Type : Other, ARC Power Supply

Material : Mild Steel

Size : Standard

Capacity : 5 kVA

Input Voltage : 220V AC

Funcion electro ot table

Funcion electro ot table

Noise Level : <50 dB

Type : Other, Electro Hydraulic Operation Table

Material : Stainless Steel & ABS

Size : Standard OT Table Size

Capacity : Patient Weight up to 250kg

Input Voltage : 220V AC, 50Hz



Back to top