10 Channel Data Logger
10 Channel Data Logger

10 Channel Data Logger

10 Channel Data Logger Specification

  • Operating Voltage
  • 230V AC
  • Interface Type
  • USB / RS232
  • Resolution
  • 16 Bit
  • Measuring Range
  • ---
  • Automation Grade
  • Semi-Automatic
  • Specimen Size
  • ---
  • Features
  • Data Storage, Multi-channel monitoring, Alarm Output, Portable
  • Hardness
  • ---
  • Equipment Type
  • 10 Channel Data Logger
  • Accuracy
  • 0.1% FS
  • Max Height
  • ---
  • Frequency
  • 50Hz
  • Temperature
  • 0C to 50C
  • Test Range
  • ---
  • Number of Specimens
  • ---
  • Response Time
  • 1 Second
  • Display Type
  • Digital LCD Display
  • Power Supply
  • 230V AC, 50Hz
  • Gas Pressure
  • ---
  • Mounting Type
  • Table Top
  • Port Size
  • ---
  • Humidity
  • ---
  • Application
  • Industrial Data Logging
  • Usage
  • Industrial, Laboratory
  • Capacity
  • ---
  • Machine Weight
  • 4.8 Kg
  • Test Speed
  • ---
  • Test Width
  • ---
  • Test Stroke
  • ---
  • Control Mode
  • Manual / PC Software
  • Number of Channels
  • 10
  • Sampling Rate
  • Programmable
  • Battery Backup
  • Inbuilt Rechargeable Battery (2 Hrs)
  • Sensor Input Type
  • Universal (Thermocouple, RTD, Voltage, Current)
  • Enclosure Material
  • ABS Plastic
  • Data Output Format
  • CSV
  • Equipment Type
  • 10 Channel Data Logger
  • Data Storage Capacity
  • 50,000 Readings
  • Software Compatibility
  • Windows compatible
  • Ingress Protection
  • IP20
  • Alarm Output
  • Buzzer / Relay
  • Dimensions
  • 250 x 165 x 120 mm
  • Clock
  • Inbuilt Real Time Clock
 
 

About 10 Channel Data Logger

10 Channel Data Logger

Display 16 x 2 Line LCD Display with back light
No. Of Channels 10 Channel
Power Supply 230V +/-10% @ 50Hz.
Temperature Range K-type Thermocouple ( 0 -700 Deg C)
ADC Resolution 16 Bit
Scan Range 1 to 100 samples/sec Menu settable 1 to 9
Auto / Manual Settable through Menu.
Signal Conditioning Signal Conditioning for Pressure and K-type Thermocouple inbuilt.
Pressure Sensor Piezo-resistive type Capacity 5PSI 0 to 200 mmWc. (Vacuum)
Load Cell Strain guage based Capacity 3.000kgms 0 to 3.000kgms
Speed Proximity sensor (PNP-Type) (0 -3000 RPM)
Date & Time RTC is provided with Battery backup.



Multi-Channel Versatility

With 10 universal input channels, this data logger supports a wide range of sensors including thermocouples, RTDs, voltage, and current, allowing simultaneous monitoring of multiple parameters. This makes it ideal for complex industrial and laboratory applications where capturing varied data points is critical for analysis.


Reliable Data Storage & Export

The logger accommodates up to 50,000 data points, ensuring extended recording without data loss. Exporting data is seamless through USB or RS232 interfaces, and the readings are saved in a user-friendly CSV format compatible with Windows software, simplifying subsequent analysis and documentation tasks.


Efficient Alarm & Backup Features

Equipped with both buzzer and relay alarm outputs, the device promptly alerts users to out-of-range values. Its inbuilt rechargeable battery provides up to 2 hours of backup operation, ensuring data integrity during power interruptions. The durable ABS enclosure and IP20 ingress protection support longevity in diverse industrial settings.

FAQ's of 10 Channel Data Logger:


Q: How do I connect sensors to the 10 Channel Data Logger?

A: You can connect a variety of sensors-including thermocouples, RTDs, voltage, and current sources-using each of the 10 universal input channels. Simply follow the corresponding input wiring instructions provided in the user manual to ensure accurate measurements.

Q: What is the process for retrieving stored data from the logger?

A: Stored data can be exported via the USB or RS232 interface in CSV format. Once connected to a Windows-compatible computer, use the supplied software to transfer, view, and analyze your recorded readings quickly and efficiently.

Q: When should I use the alarm output feature?

A: The alarm output feature, including buzzer and relay, is ideal for situations requiring immediate attention to out-of-range or abnormal values. You can program the logger to activate alarms based on defined measurement thresholds for swift responses during critical processes.

Q: Where can this data logger be installed?

A: This data logger is suitable for tabletop installation in controlled environments such as industrial facilities, laboratories, and automation systems. Its IP20 ABS plastic enclosure provides basic protection against dust and accidental contact.

Q: What benefits does the built-in battery backup provide?

A: The integrated rechargeable battery offers up to 2 hours of operation during power outages, ensuring uninterrupted data logging and protection against data loss. This is particularly useful in industrial environments where power reliability may be a concern.

Q: How can the sampling rate be adjusted on the device?

A: The sampling rate is programmable, allowing users to set the frequency of data collection according to specific application requirements. Adjustments can be made directly from the device interface or through the compatible Windows software.

Q: What advantages does the digital LCD display offer during usage?

A: The digital LCD display provides clear, real-time visualization of all monitored channels and system settings, making it easy to track sensor data, status notifications, and clock readings without requiring a computer connection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing And Measuring Equipments Category

PLC Trainer UI PLC 5D

PLC Trainer UI PLC 5D

Features : HMI integration, Interactive Simulation, Fault Injection

Usage : Laboratory, classroom

Power Supply : 220V AC, 50 Hz

Machine Weight : Approx. 13 kg

Application : Training, simulation and educational demonstration

Operating Voltage : 220V

Tile Splitting Machine (Flexural And Tensile)

Tile Splitting Machine (Flexural And Tensile)

Features : Programmable test cycles, overload protection, emergency stop

Usage : Laboratory/Industrial tile quality testing

Power Supply : 220V AC 10%, 50Hz

Machine Weight : Approx. 95 kg

Application : Flexural and tensile strength testing of ceramic tiles

Operating Voltage : 220V AC

Interlocking ISI Tile Testing Equipment

Interlocking ISI Tile Testing Equipment

Features : Sturdy build, digital display, manual and auto test modes

Usage : Laboratory / Industrial

Power Supply : 220 V AC, 50 Hz

Machine Weight : Approx. 125 kg

Application : Testing strength, durability & compression of interlocking tiles

Operating Voltage : 220 V

Antibiotic Zone Reader (Manually)

Antibiotic Zone Reader (Manually)

Features : Easy to operate, portable, stable base

Usage : Laboratory

Power Supply : 230V AC 10%, 50 Hz

Machine Weight : Approx. 2.5 kg

Application : Measurement of inhibition zones in antibiotic susceptibility

Operating Voltage : 230V AC