CONSTANT DEVIATION SPECTRMETER (CDS)
CONSTANT DEVIATION SPECTRMETER (CDS)

CONSTANT DEVIATION SPECTRMETER (CDS)

CONSTANT DEVIATION SPECTRMETER (CDS) Specification

  • Type
  • Constant Deviation Spectrometer (CDS)
  • Material
  • High Quality Metal and Glass Optical Components
  • Size
  • Standard Laboratory Size
  • Input Voltage
  • 220 V AC, 50 Hz
  • Color
  • Grey/Black Finish
  • Dimension (L*W*H)
  • Approx. 460 x 210 x 250 mm
  • Noise Level
  • Negligible / Silent Operation
  • Measurement Accuracy
  • Up to 0.5 Minutes of Arc
  • Wavelength Range
  • 350 nm to 700 nm
  • Weight
  • Approx. 8.5 kg
  • Deviation Angle
  • 30° or 60° (Depending on Model)
  • Slit Width Adjustment
  • Manual Micrometer
  • Applications
  • Spectral Analysis, Educational and Research Labs
  • Standard Accessories
  • Cylindrical Lens, Prisms, Power Cord, Instruction Manual
  • Scale Graduation
  • 0.5 Minutes
  • Spectrometer Prism Material
  • Crown Glass
  • Telescope
  • Achromatic, 175 mm Focal Length, 20 mm Aperture
  • Collimator
  • Adjustable with Achromatic Lens, 175 mm Focal Length
  • Rotating Table Marking
  • Vernier Scale with Fine Adjustment
 
 

About CONSTANT DEVIATION SPECTRMETER (CDS)



Unlock the Virtuoso of spectral analysis with our Top Constant Deviation Spectrometer (CDS), designed for superior precision and reliability. Boasting a wavelength range of 350 nm to 700 nm and choice of 30 or 60 deviation angles, this spectrometer features the Best adjustable collimator with achromatic lens. Crafted from high-quality crown glass and robust metal, it delivers measurement accuracy up to 0.5 minutes of arc. Ideal for both educational and research labs, it comes complete with standard accessories. Discount offers available - Try Now for superior results!

Superior Build and High-Quality Materials

The CONSTANT DEVIATION SPECTRMETER (CDS) utilizes high-quality metal and optical glass components, ensuring durability and precision. Trusted by educators, researchers, and laboratory professionals, this instrument delivers consistent, reliable results. Its main advantage lies in the precise scale graduations and vernier adjustments, guaranteeing measurement accuracy up to 0.5 minutes of arc. Crown glass prisms and achromatic optics ensure clarity, making it indispensable in both academic and research settings.


Efficient Packing & Dispatching for Global Reach

We prioritize efficiency in packing & dispatch to guarantee product safety and timely delivery. Constant Deviation Spectrometers are dispatched within a standard lead time, maximizing supply ability for bulk and individual orders. Our distribution network spans major export markets, ensuring prompt and secure shipment worldwide. Every CDS unit is carefully packed, and we consistently offer flexible delivery options to meet client requirements. Rely on us for consistent global supply and hassle-free dispatching.


FAQ's of CONSTANT DEVIATION SPECTRMETER (CDS):


Q: How is the Constant Deviation Spectrometer (CDS) used in laboratories?

A: The Constant Deviation Spectrometer is commonly used in educational and research laboratories for spectral analysis, enabling precise measurement of wavelengths and deviation angles in various experiments.

Q: What is the process of slit width adjustment on the CDS?

A: The slit width can be manually adjusted using a micrometer screw, allowing users to control the amount of light entering the spectrometer for enhanced measurement accuracy.

Q: When can I expect delivery after placing an order?

A: After your order is confirmed, dispatching typically occurs within the promised lead time, ensuring timely and secure delivery according to your specified export market or location.

Q: Where is the CDS manufactured and supplied from?

A: The Constant Deviation Spectrometer is manufactured and supplied by trusted distributors, exporters, and manufacturers in India, catering to local and international markets.

Q: What benefit does the Achromatic Lens provide in the CDS?

A: The achromatic lens in both the collimator and telescope reduces chromatic aberration, resulting in sharper images and higher precision during spectral analysis processes.

Q: How does the vernier scale enhance measurement accuracy?

A: The fine-marked vernier scale allows for detailed adjustment and precise readings of the deviation angle, supporting measurement accuracy up to 0.5 minutes of arc for professional applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SPEED OF SOUND USING KUNDTS TUBE EXPERIMENT

SPEED OF SOUND USING KUNDTS TUBE EXPERIMENT

Color : Transparent Tube, Black Stand

Material : Glass Tube, Metal Stand, Rubber Stoppers

Input Voltage : Not Required (manual operation)

Capacity : Single Experiment Setup

Size : Standard Laboratory Size

Noise Level : Low (depends on source frequency)

CONVEYOR BELT MODULE FOR PLC TRAINER

CONVEYOR BELT MODULE FOR PLC TRAINER

Color : Blue and Black

Material : Mild Steel

Input Voltage : 230V AC, 50Hz

Capacity : Suitable for Educational Demonstration

Size : Standard Laboratory Size

Noise Level : Low

SCR THREE PHASE HALF CONTROLLED BRIDGE CONVERTER

SCR THREE PHASE HALF CONTROLLED BRIDGE CONVERTER

Color : Blue & White

Material : High Grade Electronic Components, Powder Coated Metal

Input Voltage : Three Phase 415V AC, 50 Hz

Capacity : Up to 5A output current

Size : Laboratory Bench Type

Noise Level : Low

SODIUM LAMP SOURCE

SODIUM LAMP SOURCE

Color : Yellow/Metallic

Material : Glass and Metal

Input Voltage : 220V AC

Capacity : 35W

Size : Standard Laboratory Size

Noise Level : Silent Operation