DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD)
DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD)

DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD)

DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD) Specification

  • Type
  • Solid State Resonance Meter
  • Material
  • Non-magnetic Metallic Alloy & Dielectric Sample
  • Size
  • Standard Laboratory Bench-top
  • Input Voltage
  • 220V AC, 50Hz
  • Color
  • Grey & Blue
  • Dimension (L*W*H)
  • 350 mm x 260 mm x 180 mm
  • Capacity
  • Single Sample per Measurement
  • Noise Level
  • Negligible/Instrumental
  • Oscillator Type
  • Variable Frequency Oscillator
  • Accuracy
  • ±2%
  • Power Consumption
  • 20W
  • Calibration
  • Factory Calibrated
  • Measurement Technique
  • Resonance Method
  • Indicator Display
  • Analog Meter
  • Connection Ports
  • BNC Connectors
  • Application
  • Determination of Dielectric Constant in Solid Materials
  • Sample Holder
  • Solid Dielectric Sample Holder Included
  • Working Temperature Range
  • 0°C to 50°C
  • Accessories
  • Instruction Manual, Power Cord, Sample Tubes
  • Frequency Range
  • 10 MHz to 100 MHz
 
 

About DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD)



Get unrivaled accuracy in determining the dielectric constant of solid materials with our DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD) device. Featuring an excellent variable frequency oscillator covering 10 MHz to 100 MHz, it offers a pivotal solution for laboratory and research needs. With instant checkout, special factory calibration guarantees reliability. Equipped with BNC connectors, analog meter display, and a solid dielectric sample holder, this bench-top instrument boasts non-magnetic metallic alloy construction. Enjoy effortless operation with 2% accuracy, negligible noise level, and included essential accessories. Perfect for manufacturers, suppliers, exporters, and distributers across India.

Versatile Usage & Application Areas

The DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD) meter is designed for laboratories, universities, and research centers requiring precise solid dielectric measurements. Its usage extends to the testing of polymers, ceramics, and electronic components. Other applications include material science investigations, quality assurance, and academic experiments where accurate dielectric data is pivotal for development and innovation in electrical insulating materials.


Efficient Delivery & Trusted Certifications

We ensure prompt dispatching of your order, typically within a few days of purchase. Each instrument is delivered securely packaged, complete with instruction manual, sample tubes, and power cord. Available at the lowest price, our meter comes fully factory calibrated and complies with international standards for laboratory equipment. Charges for delivery are minimal, ensuring an affordable and smooth acquisition process for every customer.


FAQs of DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD):


Q: How does the resonance method measure the dielectric constant in solid materials?

A: The resonance method utilizes a variable frequency oscillator to create electromagnetic waves that interact with the solid dielectric sample. By analyzing the resonance frequency shift when the sample is inserted, the meter accurately calculates the dielectric constant.

Q: What types of samples can be analyzed using this instrument?

A: This instrument is suitable for testing a wide variety of solid dielectric samples, including ceramics, polymers, electronic components, and composite materials commonly found in research and industrial environments.

Q: When will my DIELECTRIC CONSTANT IN SOLIDS unit be dispatched after purchase?

A: Orders are usually dispatched promptly after order confirmation, with secure packaging to ensure safe delivery. Specific delivery timelines may vary based on your location in India.

Q: Where do I connect measurement accessories to the instrument?

A: Measurement accessories and cables should be connected via the provided BNC connectors on the instrument. The included instruction manual offers detailed guidance for proper setup and operation.

Q: What is the benefit of factory calibration for this meter?

A: Factory calibration ensures the meter operates with high accuracy and reliability, minimizing errors in dielectric constant measurement and providing dependable results for research and quality assurance.

Q: How accurate are the displayed measurements on the analog meter?

A: The instrument features an analog meter with an accuracy of 2%, allowing precise readings of the dielectric constant for various solid samples.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SPEED CONTROL OF SINGLE PHASE INDUCTION MOTOR USING MOSFET BASED PWM HALF BRIDGE INVERTER TRAINER

SPEED CONTROL OF SINGLE PHASE INDUCTION MOTOR USING MOSFET BASED PWM HALF BRIDGE INVERTER TRAINER

Type : Other, Electrical/Electronics Trainer

Material : Powder Coated Metal Enclosure with Acrylic Top

Noise Level : < 40 dB (Signal Electronics Only)

Size : Desktop Laboratory Instrument

Input Voltage : 230V AC, 50Hz

Dimension (L*W*H) : Approx. 450mm x 300mm x 150mm

PLC TRAINER (ALLEN BRADLEY 14-10 I/O)

PLC TRAINER (ALLEN BRADLEY 14-10 I/O)

Type : Other, PLC Trainer Kit

Material : Mild Steel Body with Polycarbonate Front Panel

Noise Level : Silent Operation

Size : Compact Desktop

Input Voltage : 230V AC, 50 Hz

Dimension (L*W*H) : 500 mm x 400 mm x 150 mm

ASTABLE MULTIVIBRATOR TRAINER (USING TRANSISTOR)

ASTABLE MULTIVIBRATOR TRAINER (USING TRANSISTOR)

Type : Other, Astable Multivibrator Trainer (Using Transistor)

Material : Highgrade PCB board with quality electronic components

Noise Level : Silent operation

Size : Standard educational trainer size

Input Voltage : 230V AC, 50Hz

Dimension (L*W*H) : 250mm x 180mm x 55mm

ASTABLE MULTIVIBRATOR TRAINER (741 IC)

ASTABLE MULTIVIBRATOR TRAINER (741 IC)

Type : Other, Astable Multivibrator Trainer

Material : Epoxy Coated PCB, Standard Electronic Components

Noise Level : Silent Operation

Size : Compact, BenchTop Module

Input Voltage : 230V AC, 50 Hz (via adapter), Internal supply at 12V DC

Dimension (L*W*H) : Approx. 280mm x 180mm x 60mm



Back to top