Laboratory Incubators
Laboratory Incubators

Laboratory Incubators

Laboratory Incubators Specification

  • Power Supply
  • AC Mains
  • Temperature Resistance
  • Up to 80C
  • Accuracy
  • 1C
  • Display Type
  • Digital LED
  • Glass Type
  • Toughened Glass (Viewing Window)
  • Heating Capacity
  • Ambient +5C to 80C
  • Control Type
  • Digital Temperature Controller
  • Features
  • Double Walled Construction, Adjustable Shelves, Over Temperature Protection, Uniform Air Circulation
  • Shape
  • Rectangular
  • Type
  • Laboratory Incubator
  • Dimension (L*W*H)
  • 455 x 410 x 610 mm
  • Equipment Type
  • Electric Incubator
  • Equipment Materials
  • Mild Steel Powder Coated (MS Powder Coated)
  • Power
  • 220V, 50Hz, Single Phase
  • Voltage
  • 220 Volts
  • Material
  • Stainless Steel (Inner Chamber), Powder Coated Mild Steel (Outer Body)
  • Application
  • Biological Culture, Bacterial Incubation, Microbiology
  • Capacity (Ltr)
  • 45 Liters
  • Door Type
  • Double Door (Outer Steel Door & Inner Glass Door)
  • Heating Element
  • Nichrome Wire Heater
  • Thermostat
  • Digital PID Controller
  • Safety Feature
  • Overheating Cutoff and Alarm
  • Air Circulation
  • Forced Air (Fan Assisted)
  • Number of Shelves
  • 2 (Adjustable)
  • Insulation
  • Glass Wool Insulation Between Walls
  • Chamber Finish
  • Mirror Polish (Inner Chamber)
  • Frequency
  • 50 Hz
  • Weight
  • Approx. 35 kg
  • Humidity Control
  • Optional (on Request)
 
 

About Laboratory Incubators

Laboratory Incubators

Usage/Application Laboratory
Brand Micro Technologies
Size 300x300x300 mm
Material Aluminum & SS
Frequency 50 Hz
Voltage 220/230 Volts
Ambient Temperature 80 deg C



Precision Thermal Control for Reliable Results

Equipped with a digital PID temperature controller and uniform forced air circulation, this incubator ensures precise and consistent temperature regulation throughout the inner chamber. The nichrome wire heater maintains temperatures from ambient +5C up to 80C, making it ideal for critical microbiology and bacterial incubation tasks. Over temperature protection ensures operational safety and preserves specimen integrity.


User-Friendly and Durable Construction

Featuring a double-walled structure with glass wool insulation, an outer steel door, and an inner toughened glass door, this incubator combines energy efficiency with ease of observation. The mirror-polished stainless steel inner chamber and adjustable shelves provide a hygienic and flexible workspace. Its robust powder-coated mild steel body assures durability for demanding laboratory settings.


Versatile Applications for Labs in India and Beyond

With a 45-liter capacity and optional humidity control, this electric incubator supports a wide range of biological, bacterial, and microbiological applications. Designed for use by distributors, exporters, manufacturers, suppliers, and traders, it is suitable for both research and routine laboratory environments across India.

FAQ's of Laboratory Incubators:


Q: How does the glass wool insulation enhance the performance of this laboratory incubator?

A: The glass wool insulation between the walls significantly reduces heat loss, ensuring superior thermal stability within the chamber. This creates a consistent temperature environment essential for precise incubation and energy efficiency.

Q: What is the process for setting and monitoring temperature in this incubator?

A: Temperature is set and monitored using the digital PID controller, which is operated via a digital LED display. Users can input the desired temperature within the range of ambient +5C to 80C, and the incubator maintains 1C accuracy for reliable results.

Q: When should the adjustable shelves be reconfigured?

A: The two adjustable shelves can be repositioned at any time to accommodate different sample sizes or to maximize space efficiency for various incubation needs. Move them as required depending on your vessel height or experiment type.

Q: Where is this laboratory incubator most effectively used?

A: This incubator is ideally suited for biological culture growth, bacterial incubation, and other microbiology applications in laboratory and research facilities. It's widely used by professionals in academic, industrial, and clinical settings across India.

Q: What are the main benefits of the double door (outer steel and inner toughened glass)?

A: The outer steel door provides superior insulation and safety, while the inner toughened glass door allows users to view samples without disturbing the internal environment. This reduces temperature fluctuation and supports consistent results.

Q: How does the forced air circulation system contribute to uniformity inside the incubator?

A: Forced air circulation, achieved via a fan, ensures that heated air is distributed evenly throughout the chamber. This uniform airflow eliminates temperature gradients, supporting reliable and reproducible incubation conditions.

Q: Is humidity control available for this incubator, and what applications benefit from it?

A: Yes, humidity control is available as an optional feature. It's particularly beneficial for experiments or culture processes where maintaining specific humidity levels is crucial for growth conditions, such as cell culturing or fungal incubation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware And Equipments Category

Water Still (Barnstead Type) Table Model

Water Still (Barnstead Type) Table Model

Temperature Resistance : Up to 300C

Dimension (L*W*H) : Approx. 400 x 180 x 450 mm

Power : 2000 W

Control Type : Manual

Features : Automatic Cutoff, Wall/Table Mount Design, Safe Operation

Material : Borosilicate Glass & Stainless Steel

Six Jar Test Apparatus

Six Jar Test Apparatus

Temperature Resistance : Up to 100C

Dimension (L*W*H) : 1150 x 305 x 470 mm

Power : 250 W

Control Type : Digital Speed Control

Features : Simultaneous stirring, variable speed, clear visibility, low noise, digital control

Material : Mild Steel, Stainless Steel, Polycarbonate (jars optional)

Research Polarimeter

Research Polarimeter

Temperature Resistance : Up to 40C

Dimension (L*W*H) : 420 mm x 250 mm x 380 mm

Power : 50 W

Control Type : Manual

Features : High measurement accuracy, robust build, interchangeable tubes

Material : Metal and glass

Box For Glass Specimen

Box For Glass Specimen

Temperature Resistance : Up to 100C

Dimension (L*W*H) : 300mm x 100mm x 50mm

Power : Nonelectrical

Control Type : Manual Lid

Features : Dustproof, chemical resistant finish, stackable design

Material : Aluminum, Stainless Steel



Back to top