NEWTONS RING MICROSCOPE
NEWTONS RING MICROSCOPE

NEWTONS RING MICROSCOPE

NEWTONS RING MICROSCOPE Specification

  • Type
  • Newtons Ring Microscope
  • Material
  • Metal body with optical glass components
  • Size
  • Standard laboratory size
  • Color
  • Black/Silver
  • Dimension (L*W*H)
  • Approx. 225 mm x 175 mm x 375 mm
  • Noise Level
  • Silent Operation
  • Micrometer Scale
  • Provided
  • Usage
  • Measurement of ring diameter in Newton's Ring experiment
  • Stage
  • Heavy, stable, plated stage with double lens holder
  • Illumination
  • Plano-concave mirror for reflected and transmitted light
  • Eyepiece Magnification
  • 10X (standard)
  • Measuring Range
  • 0 - 20 mm
  • Focusing Mechanism
  • Coarse and fine focusing knobs
  • Build Quality
  • Corrosion-resistant finish and robust design
  • Least Count
  • 0.001 mm
  • Objective Magnification
  • 2X (achromatic, long working distance)
  • Application
  • Physics laboratories for interference and wavelength study
  • Accessories Included
  • Optical glass plate, plano-convex lens, adjustable screws, instruction manual
  • Weight
  • Approx. 4.5 kg
 
 

About NEWTONS RING MICROSCOPE



Discover the wondrous NEWTON'S RING MICROSCOPE - highly recommended for physics laboratories and educational settings. Boasting a gorgeous, corrosion-resistant metal body, this microscope features a lofty combination of 10X eyepiece magnification and 2X achromatic objective for precise measurements. Personalise your experiment with its adjustable stage, plano-concave mirror, and micrometer scale, all housed in a robust, silent-operation design. Accessories such as an optical glass plate, plano-convex lens, and screws come included. Secure the lowest price with India's leading distributor, exporter, and supplier. Perfect for Newton's Ring interference studies!

Exceptional Features and Versatile Applications

The NEWTON'S RING MICROSCOPE is ideal for measuring the diameter of rings in Newton's Ring experiments, crucial for interference and wavelength analysis. Commonly used in physics research labs, universities, and industrial applications, it offers stable operation with a heavy plated stage, double lens holder, and both coarse and fine focusing. Simply position the optical components, adjust using the provided screws, and enjoy high-precision readings on the micrometer scale.


Sample Policy, Delivery, and Export Logistics

Benefit from streamlined export market logistics and sample availability before order placement. Samples are available for a modest charge, ensuring you can evaluate build quality and performance. With prompt and efficient logistics, our typical delivery time is swift, adhering to international shipping standards for reliability. Request samples or bulk orders with confidence-our policies are designed to facilitate smooth transactions for both domestic and overseas clients.


FAQ's of NEWTONAAAS RING MICROSCOPE:


Q: How do I use the NEWTON'S RING MICROSCOPE for an experiment?

A: To use the microscope, place the optical glass plate and plano-convex lens on the stable stage, align your sample, and adjust the focus with the coarse and fine knobs. Measure the ring diameter using the integrated micrometer scale.

Q: What makes this microscope highly recommended for laboratories?

A: Its robust metal body, lofty design, precise magnification, and corrosion-resistant finish make it a top choice for consistent, accurate results in demanding lab environments.

Q: Where can the NEWTON'S RING MICROSCOPE be applied?

A: It is widely used in physics teaching and research laboratories, especially for studying light interference and wavelength measurement using the Newton's Ring phenomenon.

Q: What is included with the NEWTON'S RING MICROSCOPE upon purchase?

A: Each unit comes with an optical glass plate, plano-convex lens, adjustable screws, an instruction manual, and a heavy, plated stage designed for professional laboratory use.

Q: What is the benefit of having both reflected and transmitted light in this microscope?

A: The plano-concave mirror provides versatile illumination for enhanced visibility of rings, facilitating precise measurement under varied experimental conditions.

Q: How can I request a sample before bulk purchase?

A: A sample can be arranged for a nominal charge. Contact our sales team, and we will guide you through the simple request and logistics process for domestic or export deliveries.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

STATIC AND DYNAMIC CHARACTERISTICS OF POWER TRANSISTOR

STATIC AND DYNAMIC CHARACTERISTICS OF POWER TRANSISTOR

Dimension (L*W*H) : Approx. 39 cm x 20 cm x 8 cm

Input Voltage : 230V AC, 50 Hz

Material : Electronic Components, PCB, Metal Casing

Size : Standard Laboratory Equipment Size

Noise Level : Silent Operation

Capacity : Supports assessment of power transistors up to 5A, 60V

CONSTANT VOLTAGE (CVT) TRAINER SCOPE OF LEARNING:

CONSTANT VOLTAGE (CVT) TRAINER SCOPE OF LEARNING:

Dimension (L*W*H) : 340mm x 250mm x 130mm

Input Voltage : 230V AC, 50Hz

Material : Highgrade ABS and Aluminium

Size : Standard Laboratory Format

Noise Level : Silent Operation

Capacity : Up to 500VA

SPARTAN6 BASED DIRECT TORQUE CONTROL OF 3PH AC INDUCTION MOTOR

SPARTAN6 BASED DIRECT TORQUE CONTROL OF 3PH AC INDUCTION MOTOR

Dimension (L*W*H) : 250mm x 200mm x 60mm

Input Voltage : 220V AC (system input), 5V/3.3V for control logic

Material : Highgrade PCB, semiconductor components, and aluminum heatsink

Size : Standard module fit for laboratory and industrial panels

Noise Level : <55 dB (controller operation)

Capacity : Suitable for 1HP to 5HP induction motors

DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD)

DIELECTRIC CONSTANT IN SOLIDS (RESONANCE METHOD)

Dimension (L*W*H) : 350 mm x 260 mm x 180 mm

Input Voltage : 220V AC, 50Hz

Material : Nonmagnetic Metallic Alloy & Dielectric Sample

Size : Standard Laboratory Benchtop

Noise Level : Negligible/Instrumental

Capacity : Single Sample per Measurement



Back to top