SCR SINGLE PHASE DUAL CONVERTER TRAINER
SCR SINGLE PHASE DUAL CONVERTER TRAINER

SCR SINGLE PHASE DUAL CONVERTER TRAINER

SCR SINGLE PHASE DUAL CONVERTER TRAINER Specification

  • Type
  • SCR Single Phase Dual Converter Trainer
  • Material
  • MS Powder Coated Panel, PCB Module, Nylon Connectors
  • Size
  • Tabletop Trainer
  • Input Voltage
  • 230V AC 10%, 50Hz
  • Color
  • Multi-color (with labeled front panel)
  • Dimension (L*W*H)
  • 380 mm x 300 mm x 120 mm
  • Capacity
  • Rated up to 1A output
  • Noise Level
  • Silent Operation
  • Learning Scope
  • Operation of dual converter in circulating and non-circulating current modes, study of converter waveforms
  • Triggering Method
  • Synchronized firing using pulse transformer
  • Indications
  • LED indication for power ON and operation status
  • Accessories
  • Instruction manual, patch cords, built-in loads
  • Output Voltage Range
  • 0-110V DC (Adjustable)
  • Test Points
  • Multiple test points provided for observation
  • Panel Display
  • Printed circuit and block diagrams with annotation
  • Power Devices
  • 4 x Silicon Controlled Rectifiers (SCRs)
  • Converter Configuration
  • Fully controlled dual converter, single phase
  • Control
  • Angle control via potentiometer
  • Weight
  • Approx. 7.5 kg
  • Protection
  • Fitted with fuses, overload, and short circuit protection
 
 

About SCR SINGLE PHASE DUAL CONVERTER TRAINER



The SCR Single Phase Dual Converter Trainer stands out as a premier educational tool, meticulously decorated for laboratory and technical training purposes. Highlighted by its invincible features-like fully controlled dual converter configuration, synchronized SCR triggering, and precise angle control via potentiometer-this trainer delivers silent operation and robust protection mechanisms. Each unit is supplied with limited stock, built-in loads, and a comprehensive instruction manual. Featuring LED indicators and multiple test points, its powder-coated MS panel conveys durability and professionalism. Order today to revolutionize your power electronics workspace!

Versatile Learning and Application

The SCR Single Phase Dual Converter Trainer is perfectly suitable for both general and specialized use in electrical labs, engineering institutes, and industrial training centers. Extra features, such as circulatory and non-circulatory mode learning with real-time waveform study, ensure comprehensive hands-on experience. MS powder-coated panel and annotated display enhance durability and clarity, while multiple protection systems make it ideal for frequent demonstration and experimentation in academic or R&D environments.


Export Logistics and Sale Information

This trainer is available for export through various FOB ports across India, with flexible payment terms including advance and letter of credit options. Main export markets span Asia, Africa, and the Middle East, with efficient logistics ensuring prompt delivery at sale price. Orders are packed securely and shipped with all accessories, so that your SCR Single Phase Dual Converter Trainer is delivered ready-to-use, supporting seamless international supply for manufacturers, distributors, and traders.


FAQ's of SCR SINGLE PHASE DUAL CONVERTER TRAINER:


Q: How does the angle control via potentiometer improve the learning process?

A: The angle control potentiometer allows users to fine-tune SCR firing angles, providing practical insight into converter operation in both circulating and non-circulating current modes, thus enhancing hands-on learning and experimentation.

Q: What safety features are incorporated in this trainer?

A: This trainer includes robust safety mechanisms such as fuses, overload protection, and short circuit protection, ensuring operational safety during laboratory experiments and preventing equipment damage.

Q: Where can the SCR Single Phase Dual Converter Trainer be used?

A: It is suitable for use in electrical engineering laboratories, technical institutes, R&D centers, and industrial settings where comprehensive training in power electronics is required.

Q: What accessories are provided with each unit for setup and usage?

A: Each trainer comes supplied with an instruction manual, patch cords, built-in loads, and a panel display with fully annotated circuit and block diagrams for convenient setup and detailed observation.

Q: How is delivery and payment arranged for international buyers?

A: International orders are processed through multiple Indian FOB ports, with flexible payment terms such as advance payment and letters of credit. Efficient export logistics ensure timely and secure delivery to diverse markets.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

DETERMINE THE CO-EFFICIENT OF THERMAL LINEAR EXPANSION OF A GIVEN METAL ROD OR LINEAR EXPANSION APPARATUS

DETERMINE THE CO-EFFICIENT OF THERMAL LINEAR EXPANSION OF A GIVEN METAL ROD OR LINEAR EXPANSION APPARATUS

Size : Standard laboratory size

Dimension (L*W*H) : Approx. 450 mm x 160 mm x 100 mm

Noise Level : N/A (Silent operation)

Color : Metallic silver with painted base

Material : Metallic (with mild steel or brass rod)

Capacity : Single rod measurement

DC MOTOR CONTROL USING 1, 2 AND 4 QUADRANT CHOPPER TRAINER

DC MOTOR CONTROL USING 1, 2 AND 4 QUADRANT CHOPPER TRAINER

Size : Standard benchtop module

Dimension (L*W*H) : Approx. 400mm x 300mm x 150mm

Noise Level : Low, suitable for laboratory environment

Color : Blue & White

Material : High quality industrialgrade components and powder coated metal cabinet

Capacity : Designed for lab demonstration and education, motor rating typically 1224V/2A

TO MEASURE THE DIAMETER OF A SMALL SPHERICAL CYLINDRICAL BODY WITH THE HELP OF VERNIER CALIPER

TO MEASURE THE DIAMETER OF A SMALL SPHERICAL CYLINDRICAL BODY WITH THE HELP OF VERNIER CALIPER

Size : Standard Laboratory Size (Caliper Length: 150 mm)

Dimension (L*W*H) : Caliper: 230mm x 80mm x 15mm (approx); Demo Kit: 250mm x 100mm x 40mm

Noise Level : Silent Operation (Manual)

Color : Metallic Silver (Caliper), Blue/Red (Objects)

Material : Stainless Steel / Brass (Body); Plastic/Foam (Spherical & Cylindrical Objects)

Capacity : Measures up to 150mm (Caliper)

STUDY OF OPERATIONAL AMPLIFIER AS V TO I & I TO V CONVERTER

STUDY OF OPERATIONAL AMPLIFIER AS V TO I & I TO V CONVERTER

Size : Benchtop module

Dimension (L*W*H) : 300 mm x 200 mm x 125 mm (approx)

Noise Level : Silent (Electrical Device)

Color : White panel with blue/black labelling

Material : PCB, Electronic Components, Acrylic Panel

Capacity : Suitable for study group or laboratory batch



Back to top