SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING)
SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING)

SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING)

SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING) Specification

  • Type
  • SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING)
  • Material
  • Premium Grade Electronic Components with High-Quality PCB
  • Size
  • Standard Laboratory/Industrial Trainer Size
  • Input Voltage
  • 230V AC, 50Hz
  • Color
  • Multi-color (as per manufacturer design)
  • Dimension (L*W*H)
  • 340 mm x 220 mm x 100 mm (Approx)
  • Capacity
  • Up to 1A Load Current
  • Noise Level
  • Silent Operation
  • Protection
  • Fuse Protection Provided
  • Weight
  • Approx. 3.5 kg
  • Output Voltage Control
  • Fully Variable
  • Cooling Method
  • Natural Air Cooling
  • Enclosure
  • Powder Coated Metal Body
  • Accessories Included
  • Patch Cords, Manual
  • Mounting Type
  • Table-Top Model
  • Load Type
  • Suitable for Resistive and Inductive Loads
  • Application
  • Educational Demonstration, Laboratory Experimentation
  • Control
  • Potentiometer Based Firing Angle Control
  • Compliance
  • Conforms to Standard Electrical Safety Norms
  • Output Type
  • DC (Rectified) Output
  • Display
  • Analog Voltmeter and Ammeter
  • Firing Mode
  • RC Triggering Circuit
  • Connectivity
  • 4mm Safety Terminals for Input and Output
 
 

About SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING)



Featured in our clearance catalog, the SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING) delivers superior performance for discerning laboratories and educational institutions. Crafted from premium-grade electronic components and a high-quality PCB, this exquisite device supports fully variable DC output with fuse protection and potentiometer-based firing angle control. The analog voltmeter and ammeter ensure precise monitoring, while natural air cooling and powder-coated metal enclosure guarantee durability. Soaring above competitors, this bargain rectifier accommodates both resistive and inductive loads and offers secure 4mm safety terminals. An ideal choice for demonstrations, supplied with essential accessories.

Competitive Advantages and Application Highlights

This rectifier stands out due to its soaring reliability, superior material grade, and exquisite build quality. Designed for educational demonstration and laboratory experimentation, its compliance with standard safety norms ensures safe, long-term use. The fully variable output and robust protection features make it a preferred choice for instructors and students in technical training institutes and research labs, providing hands-on learning with high durability.


Packaging Details and Delivery Information

Each SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING) is securely shipped in reinforced packaging to guarantee safe arrival. Delivery times are rated as prompt in the domestic market, generally within 57 business days from order confirmation. Samples are available upon request for evaluation, allowing customers to gauge quality and operational excellence before committing to larger orders.


FAQs of SCR SINGLE PHASE FULL CONTROLLED RECTIFIER (RC FIRING):


Q: How is the firing angle controlled in this rectifier?

A: The firing angle is controlled using a potentiometer, allowing precise adjustment and fully variable output voltage for tailored application requirements.

Q: What types of loads can be connected to this rectifier?

A: This rectifier is suitable for both resistive and inductive loads, making it versatile for various laboratory and demonstration tasks.

Q: When is fuse protection activated during operation?

A: Fuse protection is activated instantly upon detection of overload or short-circuit conditions, ensuring safety of the device and connected equipment.

Q: Where is this rectifier most commonly used?

A: It is primarily used in educational demonstrations and laboratory experiments in technical institutes, research centers, and industrial training facilities.

Q: What process is involved in connecting the input and output terminals?

A: Input and output connections are established via secure 4mm safety terminals, using included patch cords for reliable and safe operation.

Q: What benefits does the analog display provide?

A: The analog voltmeter and ammeter allow users to monitor output voltage and current in real-time, enabling accurate adjustments and effective teaching or experimentation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SMPS USING MOSFET TRAINER

SMPS USING MOSFET TRAINER

Input Voltage : 230V AC, 50Hz

Noise Level : Silent Operation

Dimension (L*W*H) : 340 x 200 x 110 mm

Type : Other, Educational Electronics Trainer

Size : Standard Laboratory Bench Size

Material : Powder Coated Metal & High Grade ABS Plastic

STUDY OF OPERATIONAL AMPLIFIER AS V TO I & I TO V CONVERTER

STUDY OF OPERATIONAL AMPLIFIER AS V TO I & I TO V CONVERTER

Input Voltage : 230V 10% AC, 50Hz

Noise Level : Silent (Electrical Device)

Dimension (L*W*H) : 300 mm x 200 mm x 125 mm (approx)

Type : Other, Laboratory Experiment Instrument

Size : Benchtop module

Material : PCB, Electronic Components, Acrylic Panel

1, 2 AND 4 QUADRANT CHOPPER TRAINER

1, 2 AND 4 QUADRANT CHOPPER TRAINER

Input Voltage : 230V 10% AC, 50Hz

Noise Level : Low, typically <45 dB

Dimension (L*W*H) : Approx. 400 mm x 300 mm x 150 mm

Type : Other, 1, 2 and 4 Quadrant Chopper Trainer

Size : Bench Top Trainer

Material : Highgrade mild steel body with powder coating and acrylic panel

ELECTRIC FIELD LINES AND EQUIPOTENTIAL LINES KIT

ELECTRIC FIELD LINES AND EQUIPOTENTIAL LINES KIT

Input Voltage : 3V to 12V DC (Recommended 6V DC Power Supply)

Noise Level : Silent Operation

Dimension (L*W*H) : 300 mm x 200 mm x 10 mm

Type : Other, Laboratory Experimental Kit

Size : Standard Laboratory Size

Material : Highquality Acrylic and Conductive Paper



Back to top