Analgesiometer With Pid Controller
Analgesiometer With Pid Controller

Analgesiometer With Pid Controller

Analgesiometer With Pid Controller Specification

  • Measuring Range
  • 0500 g
  • Test Range
  • Up to 500 g
  • Port Size
  • Standard
  • Display Type
  • Digital LED Display
  • Number of Specimens
  • Single Specimen at a time
  • Application
  • Measurement of pain threshold in laboratory animals
  • Accuracy
  • 1 g
  • Frequency
  • 50 Hz
  • Gas Pressure
  • 0.5 to 2.5 kg/cm
  • Temperature
  • 10C to 40C
  • Specimen Size
  • Suitable for laboratory animals (typically mice or rats)
  • Response Time
  • Instantaneous (digital)
  • Automation Grade
  • Semi-automatic
  • Power Supply
  • 230 V AC, 50 Hz
  • Max Height
  • Standard
  • Operating Voltage
  • 230V AC 10%, 50 Hz
  • Resolution
  • 1 g
  • Mounting Type
  • Table Top
  • Interface Type
  • Digital
  • Equipment Type
  • Digital Analgesiometer with PID Controller
  • Features
  • Auto stop after response, LED display, advanced control, compact design, low power consumption
  • Humidity
  • 10% to 90% RH (Non-condensing)
  • Usage
  • Laboratory testing of pain sensitivity
  • Capacity
  • 500 g
  • Machine Weight
  • Approx. 5 kg
  • Test Speed
  • Adjustable (Continuously variable)
  • Test Width
  • Standard
  • Test Stroke
  • 0 to 20 mm
  • Control Mode
  • Microprocessor-based PID Controller
  • Noise Level
  • < 60 dB
  • Dimensions
  • Approx. 260 mm × 150 mm × 210 mm
  • Compliance
  • RoHS & Laboratory Animal Protocols
  • PID Controller Type
  • Automatic Temperature & Force Regulation
  • Material of Construction
  • High grade stainless steel & ABS
  • Safety Features
  • Overload protection, emergency stop
  • Calibration
  • Factory calibrated, user adjustable
  • Accessories Supplied
  • Animal restrainer, power cord, user manual
  • Software Compatibility
  • Optional PC connectivity for data logging
 
 

About Analgesiometer With Pid Controller



Grab this featured Analgesiometer With PID Controller and experience phenomenal precision for laboratory pain threshold measurement! Engineered with an automatic temperature and force regulation microprocessor-based PID controller, it stands out inestimably in accuracy and reliability. The pristine build of high-grade stainless steel and ABS ensures enduring performance and easy maintenance. Its digital LED display, auto-stop function, and advanced safety features-including overload protection and emergency stop-promise unparalleled safety and usability. Special rate offers available for distributors, exporters, and suppliers across India. Calibration is factory-set yet user-adjustable, with optional PC connectivity for comprehensive data logging. Secure yours now!

Analgesiometer With PID Controller: Precision for Laboratory Analysis

Used for determining pain sensitivity and measuring pain threshold in laboratory animals, the Analgesiometer With PID Controller is an indispensable tool in biomedical research. Noteworthy features include automatic control of temperature and force, a high-accuracy digital display, and instantaneous response time. Its site of application spans pharmacology and laboratory research settings, particularly those testing mice or rats. The supplied animal restrainer, user manual, and factory calibration streamline laboratory workflows while ensuring pristine standards of animal welfare and experimental reproducibility.


Packaging, Export Market, and Domestic Exchange Details for Analgesiometer

Each Analgesiometer With PID Controller is carefully packaged and ready to be handed over for prompt shipment-ensuring the equipment maintains its pristine condition during transit. The main export markets are Asia, the Middle East, and Africa, making it a preferred choice for international laboratory exchanges. The proposal amount and transaction details are tailored for Indian distributors, traders, and manufacturers, supporting a seamless supply chain within the main domestic markets for scientific instrumentation.


FAQ's of Analgesiometer With Pid Controller:


Q: How does the PID controller enhance the performance of the Analgesiometer?

A: The PID controller provides automatic temperature and force regulation, ensuring inestimable accuracy and consistent testing conditions during laboratory measurements. This results in more reliable and repeatable data for pain threshold studies.

Q: What safety features are included in this Analgesiometer model?

A: This Analgesiometer is equipped with overload protection and an emergency stop function, helping safeguard users and specimens throughout the testing process.

Q: Where can the Analgesiometer With PID Controller be used?

A: It is designed for use in laboratory and research environments, especially in pharmacology, animal research facilities, and academic institutions conducting pain sensitivity studies on small laboratory animals.

Q: What is the process for calibrating the Analgesiometer?

A: The unit comes factory-calibrated for immediate use. However, users can make further adjustments as needed to maintain accurate results over time.

Q: What are the main benefits of optional PC connectivity?

A: Optional PC connectivity allows easy data logging and export of experimental results for further analysis, enhancing research efficiency and providing seamless documentation of each test session.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing And Measuring Equipments Category

PLC Trainer UI PLC 5D

PLC Trainer UI PLC 5D

Number of Specimens : 1 to 5

Display Type : Digital LCD

Measuring Range : Digital, user defined

Frequency : 50 Hz

Accuracy : 0.5%

Usage : Laboratory, classroom

Tile Splitting Machine (Flexural And Tensile)

Tile Splitting Machine (Flexural And Tensile)

Number of Specimens : single (customizable for multiple)

Display Type : Digital (LED/LCD) display

Measuring Range : 040 kN

Frequency : 50 Hz

Accuracy : 1% of indicated value

Usage : Laboratory/Industrial tile quality testing

Tile Testing Machine

Tile Testing Machine

Number of Specimens : 1 per cycle

Display Type : Digital LCD

Measuring Range : 020000 N

Frequency : 50 Hz

Accuracy : 1% of reading

Usage : Industrial/Laboratory

PLC Sap Panels

PLC Sap Panels

Number of Specimens : 1 5

Display Type : Digital LCD

Measuring Range : 0 100%

Frequency : 50 Hz

Accuracy : 0.5%

Usage : PLC Automation Control



Back to top